品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
2页 178K
描述
225 Watt Global Performance Switchers

GPM225-12 数据手册

 浏览型号GPM225-12的Datasheet PDF文件第2页 
GPC225 Commercial/GPM225 Medical  
225 Watt Global Performance Switchers  
FEATURES:  
Wide-range ac input 85-264 Vac  
2-year warranty  
Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
Commercial Approved to UL1950, IEC950 and  
CSA22.2-234 L3  
Medical Approved to UL2601-1, IEC601-1 and  
CSA22.2 No. 601  
marked to LVD  
SPECIFICATIONS:  
Ac Input  
85-264 Vac, 47-63 Hz single phase.  
line impedance and distortion. Other settings are avail-  
able to the user through adjustment of built-in potentiometer.  
Input Current  
Maximum input current at 120 Vac, 60 Hz with full rated  
output load: 5.5 A  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential  
mode. Measured with noise probe directly across output  
terminals of the power supply.  
Hold-UpTime  
20 ms minimum from loss of ac input at full load, nominal  
line (115 Vac).  
Transient Response  
500 µs typical response time for return to within 0.5% of  
final value for a 50% load step change. i/t<0.2 A/µs.  
Maximum voltage deviation is 3.5%. Startup/shutdown  
overshoot less than 3%.  
Output Power  
175 W convection; 225 W with 26 cfm air; 250 W peak. Peak  
ratings are for 60 s maximum duration, 10% duty cycle.  
Overload Protection  
Remote Sense  
Fully protected against short circuit and output overload.  
Short circuit protection is cycling type power limit.  
Recovery after fault is automatic. Factory set to begin  
power limiting at approximately 250 W.  
Provided as a standard feature.  
Voltage Adjustment  
Built-in potentiometer adjusts voltage ±5%.  
Overvoltage Protection  
EMI/EMC Compliance  
124% ± 12% typical.  
All models include built-in EMI filtering to meet the  
following emissions requirements:  
Efficiency  
EMI SPECIFICATIONS  
Conducted Emissions GPC225 EN55022 Class B; FCC Class B  
Conducted Emissions GPM225 EN55011 Class B; FCC Class B  
COMPLIANCE LEVEL  
70% at full rated load, nominal input voltage, depending  
on model and load distribution.  
Static Discharge  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
Input Protection  
Internal ac fuse provided. Designed to blow only if a  
catastrophic failure occurs in the unit.  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
EN61000-4-5, 1 kV diff., 2 kV com.  
Inrush Current  
Inrush is limited by internal thermistors. Inrush at 240 Vac  
under cold start conditions will not exceed 60 A.  
Commercial Leakage Current  
0.95 mA 254 Vac @ 60 Hz input (with no deviations).  
Commercial Safety  
Temperature Coefficient  
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950,  
EN60950 and CISPR22. UL file #E135803 commercial;  
CSA #LR46516. The output(s) are intended for safety  
earthed Signal Output and Intermediate Circuits only. All  
dc outputs are SELV under normal and single fault  
conditions.  
0.03%/°C typical on all outputs.  
Thermal Shutdown  
Provided as a standard feature. Designed to protect unit  
from prolonged over temperature.  
Environmental  
Medical Leakage Current  
Designed for 0 to 50°C operation at full rated output  
power; derate output current and total output power by  
2.5% per °C above 50°C. See Environmental and  
Packaging Specifications on next page.  
60 µA. 254 Vac @ 60Hz input.  
Medical Safety  
Approved to UL2601, CSA22.2 No. 601 Level 3 and  
IEC601. UL file E116994; CSA #LR46516. The output(s)  
are intended for safety earthed Signal Output and  
Intermediate Circuits only. The output(s) are not accept-  
able for patient connection without additional isolation. All  
dc outputs are SELV under normal and single fault  
conditions.  
Power Fail  
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms  
before output voltage drops more than 4% below nominal  
voltage upon loss of ac power. The signal is factory set to  
trip on 84 to 94 Vac brown-out depending upon incoming  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
66  

与GPM225-12相关器件

型号 品牌 获取价格 描述 数据表
GPM225-15 SLPOWER

获取价格

225 Watt Global Performance Switchers
GPM225-24 SLPOWER

获取价格

225 Watt Global Performance Switchers
GPM225-28 SLPOWER

获取价格

225 Watt Global Performance Switchers
GPM225-5 SLPOWER

获取价格

225 Watt Global Performance Switchers
GPM40-12 SLPOWER

获取价格

40 WATT GLOBAL PERFORMANCE SWITCHERS
GPM40-12G SLPOWER

获取价格

暂无描述
GPM40-15 SLPOWER

获取价格

40 WATT GLOBAL PERFORMANCE SWITCHERS
GPM40-24 SLPOWER

获取价格

40 WATT GLOBAL PERFORMANCE SWITCHERS
GPM40-28 SLPOWER

获取价格

40 WATT GLOBAL PERFORMANCE SWITCHERS
GPM40-3.3 SLPOWER

获取价格

40 WATT GLOBAL PERFORMANCE SWITCHERS