Precautions and Notes on Correct Use  
I Life Expectancy (MTTF)  
!WARNING  
Do not touch the SSR terminal section (charged section) when the  
power supply is ON. For SSRs with terminal covers, be sure to at-  
tach the cover before use. Touching the charged section may  
cause electric shock.  
The mean time to failure (MTTF) of SSRs is 100,000 hours, which  
varies with the operating conditions. To ensure long life and stable  
operation, take proper countermeasures against extremely high or  
low operating temperature, heavy fluctuations of ambient tempera-  
ture, and/or long continuous energization.  
Do not touch the SSR or the heat sink either while the power sup-  
ply is ON, or immediately after the power is turned OFF. The SSR/  
heat sink will be hot and will cause burns.  
Do not touch the SSR LOAD terminal immediately after the power  
is turned OFF. The internal snubber circuit is charged and may  
cause electric shock.  
I Input Circuit  
Input Noise  
Do not apply excessive voltage or current to the SSR input or out-  
put circuits, or SSR malfunction or fire damage may result.  
SSRs need only a small amount of power to operate. This is why the  
input terminals must shut out electrical noise as much as possible.  
Noise applied to the input terminals may result in malfunction. The  
following describes measures to be taken against pulse noise and  
inductive noise.  
Do not operate if the screws on the output terminal are loose, or  
heat generated by a terminal error may result in fire damage.  
Do not obstruct the air flow to the SSR or heat sink, or heat gener-  
ated from an SSR error may cause the output element to short, or  
cause fire damage.  
Pulse Noise  
Be sure to conduct wiring with the power supply turned OFF, or  
electric shock may result.  
A combination of capacitor and resistor can absorb pulse noise  
effectively. The following is an example of a noise absorption circuit  
with capacitor C and resistor R connected to an SSR incorporating a  
photocoupler.  
Follow the Correct Use section when conducting wiring and solder-  
ing. If the product is used before wiring or soldering are complete,  
heat generated from a power supply error may cause fire damage.  
When installing the SSR directly into a control panel so that the  
panel can be used as a heat sink, use a panel material with low  
thermal resistance such as aluminum or steel. If a material with  
high thermal resistance such as wood is used, heat generated by  
the SSR may cause fire or burning.  
Pulse width  
R
I Before Using the SSR  
Unexpected events may occur before the SSR is used. For this rea-  
son it is important to test the SSR in all possible environments. For  
example, the features of the SSR will vary according to the product  
being used.  
C
Pulse voltage  
All rated performance values listed in this catalog, unless otherwise  
stated, are all under the JIS C5442 standard test environment (15° to  
30°C, 25% to 85% relative humidity, and 86 to 106 kPa atmosphere).  
When checking these values on the actual devices, it is important to  
ensure that not only the load conditions, but also the operating envi-  
ronmental conditions are adhered to.  
The value of R and C must be decided carefully. The value of R must  
not be too large or the supply voltage (E) will not be able to satisfy  
the required input voltage value.  
The larger the value of C is, the longer the release time will be, due to  
the time required for C to discharge electricity.  
I Zero Cross Function  
An SSR with a zero cross function operates when the AC load volt-  
age approaches the zero point or its vicinity, and releases when the  
current reaches the zero point. An SSR with a zero cross function  
reduces clicking noises that may be generated when the load is  
turned ON.  
Output (load voltage)  
ON  
Pulse voltage (V)  
Input  
OFF  
Note: For low-voltage models, sufficient voltage may not be applied to  
the SSR because of the relationship between C, R, and the in-  
ternal impedance. When deciding on a value for R, check the  
input impedance for the SSR.  
Solid State Relays Technical Information  
829  

与G3J-205BLDC12-24相关器件

型号 品牌 获取价格 描述 数据表
G3J-211BL-2AC100-240 OMRON

获取价格

负载电流(mA):11.1 A;触头类型:SPST-NO(1 Form A);输出类型:A
G3J-211BLDC12-24 OMRON

获取价格

负载电流(mA):11.1 A;触头类型:SPST-NO(1 Form A);输出类型:A
G3J-S205BL OMRON

获取价格

Soft-start Solid State Contactors
G3J-S211BL OMRON

获取价格

Soft-start Solid State Contactors
G3J-S403BL OMRON

获取价格

Soft-start Solid State Contactors
G3J-S405BL OMRON

获取价格

Soft-start Solid State Contactors
G3J-T OMRON

获取价格

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
G3J-T-C OMRON

获取价格

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
G3J-T205BL OMRON

获取价格

Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically
G3J-T205BL-C OMRON

获取价格

Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output