APPLICABLE STANDARD
Operating
Storage
Temperature Range
-55 C to 85 C (1)
50 V AC
-10 C to 60 C (2)
Temperature Range
Storage Humidity Range
Operating Humidity Range
Rating
Voltage
Current
Relative humidity 85% max
(Not dewed)
0.5 A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Marking
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
×
×
×
×
ELECTRIC CHARACTERISTICS
Contact Resistance
Insulation Resistance
Voltage Proof
100 mA(DC or 1000Hz)
70 mΩ MAX .
×
×
×
-
-
×
100 V DC.
100 MΩ MIN.
150 V AC for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Insertion And
Withdrawal Forces
Mechanical Operation
Measured by applicable connector.
Insertion Force:
Withdrawal Force:
42 N MAX.
5.2 N MIN.
×
×
-
-
50 times insertions and extractions.
① Contact Resistance:
Variation from initial value 20 m or less.
② No damage, crack and looseness of parts.
① No electrical discontinuity of 1 s.
② No damage, crack and looseness of parts.
Vibration
Shock
Frequency 10 to 55 to 10Hz, approx 5min
Single Amplitude : 0.75 mm, 10 cycles
for 3 axial directions.
×
×
-
-
490 m/s2 , duration of pulse 11 ms
at 3 times for 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
(Steady state)
Exposed at 40±2 C, 90 ~ 95 %, 96 h.
① Contact Resistance:
×
×
-
-
Variation from initial value 20 m or less.
② Insulation Resistance : 100 M MIN.
③ No damage, crack and looseness of parts.
Rapid Change of
Temperature
Temperature
Time
-55
30
→
+85 C
→
30 min.
Under
5
cycles.
(Relocation time to chamber:within 2~3 MIN)
Exposed at -55℃, 96 h
Cold
① Contact Resistance:
Variation from initial value 20 m or less.
② No damage, crack and looseness of parts.
×
×
×
-
-
-
Dry Heat
Sulfur Dioxide
Exposed at 85℃, 96 h
Exposed at 25±2℃, 75±5%RH, 25 PPM for 96 h.
(Test standard : JIS C 60068)
① No defect such as corrosion which impairs
the function of connector.
② Contact Resistance:
variation from initial value 20 m or less.
No deformation of case of excessive
looseness of the terminal.
Resistance to
Soldering Heat
1)Reflow Soldering :
×
×
-
-
Peak TMP : 260℃MAX
Reflow TMP: 220℃MIN for 60sec
2) Soldering Irons : 360℃ MAX. for 5 sec.
Soldered at solder temperature
240±3℃ for immersion duration, 3 sec.
A new uniform coating of solder shall cover a
minimum of 95 % of the surface being immersed.
Solderability
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(1) Include temperature rise caused by current-carrying.
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
HT.YAMAGUCHI
HT.YAMAGUCHI
KS.NAKAJIMA
KS.NAKAJIMA
20200820
20200820
20200820
20200820
(2) “STORAGE” means a long-term storage state for the unpacked part
before assembly to PCB.
Unless otherwise specified, refer to JIS-C-5402.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
ELC-336339-20-00
FX20-60S-0.5SV(20)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CODE NO.
CL570-1102-8-20
FORM HD0011-2-1