FR201 THRU FR207
2.0 AMPS. Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
2.0 Amperes
DO-15
Features
ꢀ
ꢀ
ꢀ
ꢀ
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
ꢀ
ꢀ
ꢀ
Cases: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: Axial leads, solderable per MIL-
STD-202, Method 208 guaranteed
Polarity: Color band denotes cathode end
High temperature soldering guaranteed:
260℃/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs.,(2.3kg) tension
Weight: 0.40 gram
ꢀ
ꢀ
ꢀ
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol FR
201 202 203 204
50 100 200 400 600 800 1000
35 70 140 280 420 560 700
FR
FR
FR
FR
FR
FR
Type Number
Units
205 206 207
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
V
V
V
VRRM
VRMS
VDC
Maximum DC Blocking Voltage
50 100 200 400 600 800 1000
Maximum Average Forward Rectified
Current.375”(9.5mm) Lead Length
@TA = 55℃
2.0
A
I(AV)
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 2.0A
60
A
V
IFSM
1.2
VF
IR
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=100℃
5.0
100
uA
uA
nS
pF
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance ( Note 3 )
Trr
Cj
150
250
500
30
60
18
5
RθJA
RθJL
RθJC
OC/W
Operating Temperature Range
Storage Temperature Range
℃
℃
TJ
-65 to +150
TSTG
-65 to +150
Notes:1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4.0 Volts D.C.
3. Mount on Cu-Pad Size 10mm x 10mm on P.C.B.
- 406 -