APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-40 C TO 85 C
-10 CTO50C
(PACKEDCONDITION)
TEMPERATURE RANGE
OPERATINGORSTORAGE
HUMIDITY RANGE
50 V AC / DC
RATING VOLTAGE
CURRENT
RELATIVEHUMIDITY 90 %MAX(NOTDEWED)
APPLICABLE CABLE
t=0.3±0.05, GOLD PLATING
0.5 A (note 1)
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
×
×
×
×
MARKING
CONFIRMED VISUALLY.
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE 1 mA (DC OR 1000Hz).
50 m MAX.
×
×
INCLUDING FPC, FFC BULK RESISTANCE
(L=8 mm)
INSULATION
RESISTANCE
VOLTAGE PROOF
100 V DC.
500 M MIN.
×
×
×
×
150 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
20 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
50 m MAX.
×
×
-
-
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
VIBRATION
SHOCK
FREQUENCY 10 TO 55 Hz, HALF AMPLITUDE
0.75 mm FOR 10 CYCLES IN
3 AXIAL DIRECTIONS.
981 m/s2, DURATION OF PULSE 6 ms AT 3 TIMES
IN 3 BOTH AXIAL DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 1 s.
② CONTACT RESISTANCE:
50 m MAX.
③ NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
×
×
-
-
FPC RETENTION FORCE MEASURED BY APPLICABLE FPC.
(CONNECTOR, FPC AT INITIAL CONDITION.
DIRECTION OF INSERTION: 0.4×n N MIN
(note 2)
(n : NUMBER OF CONTACTS)
THICKNESS OF FPC SHALL BE t=0.3 mm )
ENVIRONMENTAL CHARACTERISTICS
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE-40→+15TO+35→+85→+15TO+35C ① CONTACT RESISTANCE:
50 m MAX.
×
-
TIME
30→ 2 TO 3 → 30→ 2 TO 3 min. ② INSULATION RESISTANCE: 50 M MIN.
UNDER 5 CYCLES.
③ NO DAMAGE, CRACK OR LOOSENESS
DAMP HEAT
(STEADY STATE)
OF PARTS.
EXPOSED AT
RELATIVE HUMIDITY 90 TO
40±2 C,
×
×
-
-
95 %, 96 h.
96 %,
DAMP HEAT,CYCLIC
EXPOSED AT
RELATIVE HUMIDITY 90 TO
10 CYCLES, TOTAL
-10 TO +65 C,
① CONTACT RESISTANCE:
50 m MAX.
② INSULATION RESISTANCE: 1 M MIN.
(AT HIGH HUMIDITY)
240 h.
③ INSULATION RESISTANCE: 50 M MIN.
(AT DRY)
④ NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
DRY HEAT
EXPOSED AT 85±2 C, 96 h.
EXPOSED AT -40±3 C, 96 h.
① CONTACT RESISTANCE:
50 m MAX.
×
×
×
-
-
-
② NO DAMAGE, CRACK OR LOOSENESS
COLD
OF PARTS.
CORROSION SALT MIST
EXPOSED AT 35±2 C 5% SALT WATER SPLAY ① CONTACT RESISTANCE:
FOR 96 h.
50 m MAX.
② NO EVIDENCE OF CORROSION WHICH
AFFECTS TO OPERATION OF
CONNECTOR.
SULPHUR DIOXIDE
[JIS C 60068-2-42]
EXPOSED AT 40±2 C, RELATIVE HUMIDITY
80±5 %, 25±5 ppm FOR 96 h.
×
×
-
-
HYDROGEN SULPHIDE
[JIS C 60068-2-43]
EXPOSED AT 40±2 C, RELATIVE HUMIDITY
80±5 %, 10 TO 15 ppm FOR 96 h.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HS.HIRAHARA
HS.HIRAHARA
NM.YONEYAMA
DS.HIROWATARI
20210406
20210406
20210330
20210326
Unless otherwise specified, refer to JIS C 5402 and IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-337397-98-00
FH12A-**S-0.5SH(1)(98)
CL528
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
1/2
△
FORM HD0011-2-1