FF-SPS4
• Type 4 according to IEC/EN 61496 - parts 1 & 2
• Scanning range up to 75 m / 246 ft without adjustment
• ø35 mm / 1.4 in. detection capability
®
NRTL/C
• Meets applicable parts of US OSHA, ANSI and RIA
for Control Reliability
Dimensions in millimeters / inches, meters / feet, weights in kg / lbs
Specifications
Power supply voltage
Power consumption
Output switching capacity
Material
120 Vac or 240 Vac (+10%, -20%)
24 Vdc, ±15%(1)
Standard 8 / Long. range: E = 4 VA/3 W, R = 6 VA/5 W - Lens heating: E = 7 VA, R = 9 VA
2 A/250 Vac, 2 safety relays with guided contacts (10 mA min.)
Housing: Aluminium alloy, yellow painted according to RAL 1021 (polyurethane)
Front face: polycarbonate
Dimensions Terminal: 187x120x50 mm (7.4x4.7x2.0 in.) / Connector: 277x120x50 mm (10.9x4.7x2.0 in.)
Lens emitter: ø35 mm (1.4 in.) / Lens receiver: ø35 mm (1.4 in.)
Emission
Power supply frequency
Resolution
Modulated infrared (880 nm), 2 selectable emission frequencies (50 Hz and 40 Hz)
48 to 62 Hz (for the power supplies 120 Vac or 240 Vac)
ø35 mm / 1.4 in.
Alignment tolerance
Ambient temperature
Sealing
±2° in compliance with IEC/EN 61496 - 2 requirements
Standard: 0 to 55°C (32 to 131°F) / Lens heating: -25 to 55°C (-13 to 131°F)
Terminal: IP 67 or NEMA 6 / Connector: IP 65 or NEMA 4 and 13
Electrical: IEC 801-4, level IV / Electromagnetic: IEC 801-3, level IV
Sun: 20 000 Lux / Lamp: 15 000 Lux
Noise immunity
Immunity to ambient light
Status indicator
LEDs display on unit front face
Scanning range
Standard: 0.5 to 40 m (1.6 to 131.2 ft) / Lens heating: 0.5 to 20 m (1.6 to 65.6 ft) /
Long range: 30 to 75 m (98.4 to 246 ft)
Electrical connection
Connecting terminals: snap-in clips or DIN 43652 connector model
DIN 43652
connector model
T15 Torx screw
Ordering information (Emitter/Receiver) (2)
FF-SPS4 ❏❏R ❏
Cover
Power supply voltage:
E: 120 Vac
G: 240 Vac
2: 24 Vdc
M 6
M 6
50/1.97
(1)
Electrical wiring:
T: Terminal strip (snap-in-clip)
32/1.26
C: DIN 43652 connector
Female plug
62.5/ 2.46
31/
1.22
Scanning range:
4: 0.5 to 40 m / 1.6 to 131.2 ft
94/3.70 ± 0.25/0.009
T15 Torx screws
49.5/1.95
(standard model)
2: 0.5 to 20 m / 1.6 to 65.6 ft
(lens heating model, available with
terminal strip and Vac supply only)
7: 30 to 75 m / 98.4 to 246 ft
(long range)
Terminal strip model
2 M6 holes, 8/0.31 depth
cover
(connecting terminal: snap-in-clips)
Note
(1) - DC versions are featured with a galvanic
insulation (DC to DC converter) that provides
immunity to external disturbances; this is
essential to guarantee the safety integrity of the
equipment.
M 6
M 6
29 (R)
PG 16 (R)/PG 11 (E)
27 (E)
cable gland (and
reducer for the
emitter)
94/3.70 ± 0.25/0.009
65 ± 0.25 / 2.56 ± 0.009
4 M6 holes, 8/0.31 depth
(2) - The equipment is delivered with two
standard brackets and two separate plugs (for
the FF-SPS4❏C❏❏ models) or two cable glands
and one reducer (for the FF-SPS4❏T❏❏
models).
Emitter
Receiver
Response time (10-3 sec) t1
20
Mass per device
kg/lbs
1.15 / 2.5
1.35 / 3.0
108
• Industrial Safety Products •