5秒后页面跳转
EDC334Z5R5C PDF预览

EDC334Z5R5C

更新时间: 2024-11-12 14:51:59
品牌 Logo 应用领域
CDE /
页数 文件大小 规格书
4页 661K
描述
EDC334Z5R5C

EDC334Z5R5C 数据手册

 浏览型号EDC334Z5R5C的Datasheet PDF文件第2页浏览型号EDC334Z5R5C的Datasheet PDF文件第3页浏览型号EDC334Z5R5C的Datasheet PDF文件第4页 
Type EDC, 70 ºC Long Life Electric Double Layer Supercapacitor  
Type EDC, 70 ºC electric double layer supercapacitors offer high  
capacitance values in a thru hole stacked coin type package.  
Primarily designed for integrated circuit voltage backup, the  
capacitors can also be used to deliver the initial power from  
batteries.  
Highlights  
- Long life  
- High discharge current  
- 70 ºC Operating temperature  
Specifications  
Operating Temperature Range  
–25 ºC to +70 ºC  
5.5 Vdc to 6.3 Vdc  
0.047 F to 1.5 F  
Rated Voltage Range  
Capacitance Range  
Life, Moisture and Temperature Characteristics  
After the following procedures have been performed, measure the  
capacitance and ESR at +20 ºC.  
Life Test:  
Apply the max. operating voltage for 1000 h at +70 ºC  
Capacitance Change ±30% of the initial measured value  
ESR ≤ 4 times the initial specified value  
Shelf Life:  
Subject the capacitor to 1000 hours without voltage at +70 ºC.  
Capacitance Change ±30% of the initial measured value  
ESR ≤ 4 times the initial specified value  
Moisture Resistance:  
Subject the capacitor to 240 hours at +40 ºC at 90 to 95% RH  
without voltage.  
Capacitance Change ±30% of the initial measured value  
ESR ≤ 3 times the initial specified value  
Temperature Cycling  
Stabilize the capacitor at each of the following temperatures for 1  
hour in sequence, and then measure the capacitance and ESR at  
that temperature.  
1. +20 ºC  
2. -25 ºC  
3. +20 ºC  
4. +70 ºC  
5. +20 ºC  
Capacitance Change (at -25 ºC) ±30% of the initial measured value  
ESR (at -25 ºC) ≤ 5 times the initial measured value  
Capacitance Change (at +85 ºC) ±30% of the initial measured value  
ESR (at +85 ºC) ≤ 4 times the initial measured value  
Capacitance Change (Step 5 at +20 ºC) ±10% of the initial measured value  
ESR (Step 5 at +20 ºC) meets the initial specified value  
Regulatory Information  
CDE Cornell Dubilier 1661 E. Rodney French Blvd. New Bedford, MA 02744 Phone: (508)996-8561 Fax: (508)996-3830