5秒后页面跳转
DRC3P48B420R2 PDF预览

DRC3P48B420R2

更新时间: 2024-09-15 02:54:31
品牌 Logo 应用领域
快达 - CRYDOM /
页数 文件大小 规格书
2页 536K
描述
DIN Rail Mount

DRC3P48B420R2 数据手册

 浏览型号DRC3P48B420R2的Datasheet PDF文件第2页 
InstallationDISN RhaileMeoutnt  
SOLICON DRC Series 3 Phase & Reversing  
Solid State Contactors  
This installation sheet includes detailed mounting and wiring instructions which apply  
for Crydom SOLICON DRC 3 Phase and Reversing Solid State Contactors. Be sure to  
visit the product series' datasheet available at the Crydom website to complement  
this information. If you have questions or need additional information please contact  
Crydom Tech Support.  
PART NUMBER NOMENCLATURE  
DIN Rail Mount  
Load Current per Phase  
4: 7.6 Amp FLA  
(x2 Controlled Legs  
& 3R function);  
4.8 Amp FLA  
(x3 Controlled Legs only)  
Operating Voltage  
40: 400 VAC  
(3R function only)  
48: 480 VAC  
Switching Mode  
(3P function only)  
Blank: Zero Voltage Turn-On  
R: Instantaneous Turn-On  
60: 600 VAC  
(3P function only)  
Series  
4
DRC 3P 48  
D
00  
R
2
Please read all mounting instructions before using your SOLICON DRC Series Solid State  
Contactor.  
Controlled Legs  
Function  
Auxiliary Contacts  
Control Voltage  
A: 208-265 VAC  
B: 90-140 VAC  
C: 36-55 VAC/DC  
D: 18-30 VAC/DC  
(3P function only)  
18-30 VAC  
(3P function only)  
Blank: 3 Controlled Legs  
2: 2 Controlled Legs  
3P: Contactor  
3R: Reversing Contactor  
00: Not included  
11: Solid State,  
1 N.O. + 1 N.C.  
MOUNTING INSTRUCTIONS (A,B)  
To install on DIN rail  
Install the contactor on the DIN  
(3P function only)  
rail (as shown in fig.1).  
20: Solid State, 2 N.O.  
33: EMR, 1 N.O. + 1 N.C.  
(3P function, D option only)  
40: EMR, 2 N.O.  
Wire the contactor to the input  
(3R function only)  
E: 18-30 VDC  
(3R function only)  
side. AWG #18 (1 mm2) minimum,  
To remove from  
N.O.: Normally Open  
N.C.: Normally Closed  
AWG #12 (4 mm2) x 2 maximum.  
DIN rail  
(3P function, D option and  
3R function, E option only)  
Wire the contactor to the output  
side. AWG #18 (1 mm2) minimum,  
AWG #10 (6 mm2) x 2 (stranded/sol-  
Required for valid part number  
For options only and not required for valid part number  
id) maximum.  
WIRING DIAGRAM  
fig. 1  
L1  
L2  
L3  
Maximum recommended terminal  
screw torque input 12 lb-in (1.36  
Motor Controller /  
AC-53a Application  
Nm) & output 15 lb-in (1.7 Nm).  
fig. 2 Terminal  
screw type.  
Top/Bottom view.  
T1  
T2  
T3  
If multiple units are installed be  
sure to follow derating curves  
L1  
A3  
L2  
L3  
WARNING! Removing product from 35 mm rail incorrectly by not using the  
appropriate tool could damage the latching system  
13  
21/23  
A1  
M
(E,F)  
3
(D,F)  
Overload current  
protection needs to  
be considered  
CONTROL  
INPUT  
(Forward)  
(C)  
DRC3  
TABLE 1. HP Ratings at Nominal Voltage  
IND. CONT. EQ.  
CONTROL  
INPUT  
(Reverse)  
[DRC3R  
Ambient  
DRC3P48x4x@480 VAC DRC3P48x4x2@480 VAC DRC3R40x4x  
@ 400 VAC  
DRC3R48x4x  
@ 480 VAC  
Temperature DRC3P60x4x@600 VAC DRC3P60x4x2@600 VAC  
XXXX  
INPUT  
STATUS  
40ºC  
60ºC  
80ºC  
3 HP / 2.2 kW  
2 HP / 1.5 kW  
1 HP / 0.75 kW  
5 HP / 3.7 kW  
3 HP / 2.2 kW  
1.5 HP / 1.1 kW  
3 HP / 2.2 kW 5 HP / 3.7 kW  
2 HP / 1.5 kW 3 HP / 2.2 kW  
3/4 HP / 0.55 kW 1 HP / 0.75 kW  
model only]  
General Use /  
AC-51 Application  
14  
22/24  
A2  
T1  
T2  
T3  
COMMON  
FOR CONTROL  
INPUT  
T1  
T2  
T3  
DERATING CURVES(C)  
DRC3P (3 legs controlled)  
Single unit  
Multiple units  
6
5
4
3
2
1
0
T1  
T2  
T3  
0.9 in  
[22 mm]  
Minimum  
Important Considerations  
3.15 in  
[80 mm]  
Minimum  
Be sure to use input and output voltages within operating  
ranges.  
LED indicates only input status. It does not represent output  
status.  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
To achieve maximum ratings, there must be a minimum  
spacing of 0.8 in (22 mm) between the devices in free air and  
a minimum free spacing of 3.15 in (80 mm) at the top and at  
the bottom. (See fig. 3)  
3.15 in  
[80 mm]  
Minimum  
DRC3P (2 legs controlled) & DRC3R  
Single unit  
Multiple units  
8
7
6
5
4
3
2
1
0
fig. 3 Multiple units mounting for maximum ratings  
General Notes  
(A) See compatible accessories in corresponding datasheet.  
(B) For optimal thermal performance, contactor vents should be aligned vertically to maximize natural convection  
airflow.  
(C) To achieve maximum ratings, there must be a minimum spacing of 0.8 in (22 mm) between the devices in free air  
and a minimum free spacing of 3.15 in (80 mm) at the top and at the bottom. (see fig. 3)  
(D) Normally Open (13 - 14) for DRC3xxxx411, DRC3xxxx420, DRC3xxxx433 and DRC3xxxx440 models.  
(E) Normally Open (23-24) for DRC3xxxx420 and DRC3xxxx440 models, Normally Closed (21-22) for DRC3xxxx411 and  
DRC3xxxx433 models.  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
(F) Not available for DRC3xxxx400 models.  
Rev. 051617  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  

与DRC3P48B420R2相关器件

型号 品牌 获取价格 描述 数据表
DRC3P48B433R2 CRYDOM

获取价格

DIN Rail Mount
DRC3P48B440R2 CRYDOM

获取价格

DIN Rail Mount
DRC3P48C400 CRYDOM

获取价格

DIN Rail Mount
DRC3P48C4002 ETC

获取价格

RELAY SSR 480 V
DRC3P48C400R ETC

获取价格

RELAY SSR 480 V
DRC3P48C400R2 CRYDOM

获取价格

DIN Rail Mount
DRC3P48C411 CRYDOM

获取价格

DRC Series
DRC3P48C4112 ETC

获取价格

RELAY SSR 480 V
DRC3P48C411R ETC

获取价格

RELAY SSR 480 V
DRC3P48C411R2 CRYDOM

获取价格

DIN Rail Mount