Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
157
FX-301-F7 FX-301-F
■General terms and conditions............. F-3
Glossary of terms / General precautions....P.1549~ / P.1552~
■Selection guide ……………………… P.3~
■Korea's S-mark............................. P.1602
FIBER
SENSORS
Related Information
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Recognition
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Certified
(FX-301-F only)
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
PNP output
Light intensity
Timer
Automatic
type available monitor
STATIC
CONTROL
DEVICES
LASER
Easy operation even for beginners!
Optimum settings can be realized with simple operations
MARKERS
PLC
HUMAN MACHINE
INTERFACES
FX-301-F7
For use with leak detection or liquid detection fiber only
Sets the optimal threshold value
ENERGY
MANAGEMENT
SOLUTIONS
Incident light
intensity
(During teaching)
The FX-301-F7 (Note 1) dedicated for the leak detection fiber FD-F71
and the FX-301-F dedicated for the liquid detection fiber FT-F93 are
available. Optimal setting is possible with easy operation.
Note: The FX-301-F can be also used by setting it to leak detection mode. However, the
functions are different from the FX-301-F7 dedicated for the leak detection fiber,
so it is recommended to use the FX-301-F7 when using the leak detection fiber.
Threshold value will
be set automatically to
-20 % of the incident
light intensity during
the teaching to steadily
detect the leak. It is also
possible to change the
threshold value to -15 %
or -30 %.
FA COMPONENTS
-15 %
-20 %
-30 %
(At the time of factory shipment)
MACHINE VISION
SYSTEMS
Threshold value
UV CURING
SYSTEMS
Leak detection fiber
Liquid detection fiber
FD-F71
FT-F93
Threshold follow-up function
FX-301-F7
Selection
Guide
Incident
light
Incident light intensity is
checked at regular time
interval (10 min.), and
threshold value is reset
automatically.
Fibers
intensity
(Current value)
Fiber
Amplifiers
Threshold
value
Other Products
Dedicated amplifier for the
leak detection fiber
FX-301-F7
Dedicated amplifier for the
liquid detection fiber
FX-301-F
Time
FX-300
FX-311
*Function is set to OFF at the time of factory shipment.
Flashing function incorporated
FX-301-F7/
FX-301-F
FX-11A
When the leak detection fiber is connected (F7 mode), if
a leak is detected, you will recognize which fiber detects
the leak at a single glance because the emitter will start
flashing.
FX2
FX-CH2
FX-CH
Easy maintenance, as main and sub units are identical
Both main and sub units utilize the same amplifier body. This
feature allows for easy mounting in the side-by-side configuration.
Long life and stable operational settings due
to the newly developed emitting element
The main and sub unit
Sub cable
functions are distinguished
only by the proper use of
3-core main cable and the
1-core sub cable.
Moreover, by utilizing the same
body for both main and sub
units, inventory management
and maintenance is simplified.
The newly developed “four-chemical emitting element”
used for FX-301-F7 / FX-301-F can suppress the
secular change of the light emitting element to minimum,
allowing stable detection for long period of time.
Main cable