5秒后页面跳转
CLSA-12 PDF预览

CLSA-12

更新时间: 2024-09-16 02:52:19
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
2页 84K
描述
CLAMP-ON CURRENT SENSOR

CLSA-12 数据手册

 浏览型号CLSA-12的Datasheet PDF文件第2页 
MODEL: CLSA  
•AC power input module (model: R3-WT4A)  
CLAMP-ON CURRENT SENSOR  
Functions & Features  
•Special cable for CLSA-08, -12 (model: CLSA-08C-30)  
•Easy-to-install, nylon spring-loaded, clamp-on type current  
sensor  
•Over-voltage clamp element for safety in open circuit  
•Wide frequency band  
GENERAL SPECIFICATIONS  
Construction: Clamp  
Connection  
CLSA-08, CLSA-12: Connector  
(Connector model: SMR-02V-B)  
CLSA-30, CLSA-50: Leadwire  
Housing material: Nylon  
Applicable wire size: AWG22 or thicker (Max. 30 meters,  
twisted)  
Detachable number of times: Approx. 100 times  
MODEL: CLSA–[1]  
INPUT SPECIFICATIONS  
Max. working voltage: 440 V AC (primary side)  
ORDERING INFORMATION  
• Code number: CLSA-[1]  
Operational range & overload capacity  
(Operational range: Overload capacity)  
Specify a code from below for [1].  
(e.g. CLSA-08)  
CLSA-08: 80 A maximum 120 A continuous  
CLSA-12: 120 A maximum 300 A continuous  
CLSA-30: 300 A maximum 360 A continuous  
CLSA-50: 500 A maximum 600 A continuous  
Caution 1: The output values may vary depending on the  
accuracy of engagement at the clamp connection.  
Caution 2: The sensor’s mechanical construction may cause  
it to generate resonance sound. However, it does not affect  
the perfomrance of the sensor.  
Confirm the correct sensor type described on the data sheet  
of the combined transducer/transmitter module.  
[1] INPUT  
08: 80 A  
12: 120 A  
30: 300 A  
50: 500 A  
INSTALLATION  
CAUTION  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Fix with a binding strap.  
Weight  
Before you remove the sensor module or mount it, turn off  
the input signal for safety. While the line is alive, the  
module’s cores, attracted to each other, may be hard to  
separate.  
CLSA-08: 45 g (1.6 oz)  
CLSA-12: 70 g (2.5 oz)  
CLSA-30: 200 g (7.1 oz)  
RELATED PRODUCTS  
■ CLSA-08, 12, 30 and 50  
CLSA-50: 300 g (10.6 oz)  
•AC current input module (model: R3-CT4A)  
•AC current input module (model: R3-CT8A)  
•AC current input module (model: R5T-CTA)  
•AC current transducer (model: 14CEC)  
•AC current transducer (model: LTCEC)  
•CT transmitter (model: CTC)  
PERFORMANCE in percentage of span  
Accuracy: ±1 % (45 – 65 Hz)  
±2 % (65.1 Hz – 1.2 kHz)  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
(sensor core to output)  
•High AC current transmitter (model: CTCS)  
•CT transmitter (model: KCEC)  
Dielectric strength: 1000 V AC @ 1 minute  
(sensor core to output)  
•AC current transmitter (model: M2CEC)  
•CT transmitter (model: M5CTC)  
•CT converter (model: M8CTC)  
■ CLSA-08, 12  
•Multi power input module (model: R3-WT1A)  
http://www.m-system.co.jp/  
CLSA SPECIFICATIONS  
ES-9282 Rev.6 Page 1/2  

与CLSA-12相关器件

型号 品牌 获取价格 描述 数据表
CLSA1206 RIEDON

获取价格

Current Sensing Chip Resistor
CL-SA-12C-02 NIDEC

获取价格

SLIDE SWITCHES
CL-SA-12C-22 NIDEC

获取价格

SLIDE SWITCHES
CL-SA-12C4-02 NIDEC

获取价格

SLIDE SWITCHES
CL-SA-12C4-22 NIDEC

获取价格

SLIDE SWITCHES
CLS-A2 ETC

获取价格

Safety magnetic sensors Magnetic units
CLSA2010 RIEDON

获取价格

Current Sensing Chip Resistor
CLSA2512 RIEDON

获取价格

Current Sensing Chip Resistor
CLSA25120500OHMS RIEDON

获取价格

Current Sensing Chip Resistor
CLSA-30 MSYSTEM

获取价格

CLAMP-ON CURRENT SENSOR