BTA412Y-800ET
3Q Hi-Com Triac
23 November 2018
Product data sheet
1. General description
Planar passivated high commutation three quadrant triac in a IITO-220 internally insulated plastic
package. This "series ET" triac balances the requirements of commutation performance and gate
sensitivity and is intended for interfacing with low power drivers including microcontrollers. It is
used in applications where " high juction operating temperature " capability is required.
2. Features and benefits
•
3Q technology for improved noise immunity
•
•
•
•
•
•
•
•
•
High commutation capability with sensitive gate
High blocking voltage capability
Direct interfacing with low power drives and microcontrollers
High juction operating temperature (Tj(max) = 150 °C)
Isolated mounting base with 2500 V (RMS) isolation
Internally insulated package
Planar passivated for voltage ruggedness and reliability
Good immunity to false turn-on by dV/dt
Triggering in three quadrants only
3. Applications
•
•
•
•
•
•
Electronic thermostats (heating and cooling)
Motor controls e.g. vacuum cleaners
Refrigeration and air-conditioner compressor controls
Excellent for AC switching and phase control such as heating, lighting
Typical applications are AC solid-state switches, light, dimmers, power tools
High juction operating temperature (Tj(max) = 150 °C)
4. Quick reference data
Table 1. Quick reference data
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
VDRM
repetitive peak off-
state voltage
-
-
800
V
IT(RMS)
ITSM
RMS on-state current
full sine wave; Tmb ≤ 118 °C; Fig. 1;
Fig. 2; Fig. 3
-
-
-
-
-
-
-
-
12
A
non-repetitive peak on- full sine wave; Tj(init) = 25 °C;
state current
140
150
150
A
tp = 20 ms; Fig. 4; Fig. 5
full sine wave; Tj(init) = 25 °C;
tp = 16.7 ms
A
Tj
junction temperature