Limit Alarms (potentiometer adj.) A-UNIT

ASP-1144-P 数据手册

 浏览型号ASP-1144-P的Datasheet PDF文件第2页浏览型号ASP-1144-P的Datasheet PDF文件第3页浏览型号ASP-1144-P的Datasheet PDF文件第4页 
MODEL: ASP  
Limit Alarms (potentiometer adj.) A-UNIT  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
FREQUENCY ALARM  
(50 Hz minimum)  
Functions & Features  
• Providing SPDT relay outputs at preset frequency levels  
• Dual (Hi/Lo) trip  
[4] POWER INPUT  
AC Power  
• Low-end cutout  
• Energized or de-energized coil at a tripped condition  
selectable  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Deadband (hysteresis) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
Typical Applications  
• Annunciator  
DC Power  
S: 12 V DC  
• Various alarm applications  
R: 24 V DC  
V: 48 V DC  
P: 110 V DC  
50  
(1.97)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
80  
(3.15)  
Connection: M3.5 screw terminals  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Zero adjustment: -5 to +5 % (front)  
132  
(5.20)  
Span adjustment: 95 to 105 % (front)  
Setpoint adjustments: 270°-turn screwdriver adjustments  
(front); 0 – 100 % independently  
mm (inch)  
Remark: The ASP has low-end cutout function below 2 – 5 %  
input. A setpoint below this equals 0 %.  
Hysteresis (deadband) adjustments: 1 – 100 % (front)  
Front LEDs: LED turns on at a tripped condition; red for  
output 1, green for output 2  
MODEL: ASP-[1]1[2][3]-[4]  
ORDERING INFORMATION  
• Code number: ASP-[1]1[2][3]-[4]  
Specify a code from below for each of [1] through [4].  
(e.g. ASP-1111-B)  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
• Frequency range (e.g. 0 – 500 Hz)  
Low-end cutout: 2 to 5 %  
INPUT SPECIFICATIONS  
[1] INPUT  
1: Dry contact  
2: Voltage pulse  
Frequency range: 0 – 50 Hz through 10 kHz  
Pulse width (time) requirement: Duty ratio 20 – 80 % at 100  
% input  
Dry Contact: Mechanical contact or open collector  
Sensing: Approx. 7.5 V DC @1 mA  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2 V for OFF  
Voltage Pulse: Square or sine waveforms  
Input pulse sensing: Capacitor coupled; detecting pulse rise  
Input amplitude: 2 – 50 Vp-p  
Input impedance: 100 kΩ min.  
ASP SPECIFICATIONS  
ES-2156 Rev.5 Page 1/4  
http://www.m-system.co.jp/  

与ASP-1144-P相关器件

型号 品牌 获取价格 描述 数据表
ASP-1144-R MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-1144-S MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-1144-V MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-114779-01 SAMTEC

获取价格

Board Connector, 30 Contact(s), 2 Row(s), Male, Straight, Surface Mount Terminal
ASP11TEB CIT

获取价格

CIT SWITCH
ASP11TEC CIT

获取价格

CIT SWITCH
ASP11TED CIT

获取价格

CIT SWITCH
ASP11TEH CIT

获取价格

CIT SWITCH
ASP11TES20 CIT

获取价格

CIT SWITCH
ASP11TES25 CIT

获取价格

CIT SWITCH