AMIS−52150
OPERATING AND MAXIMUM SPECIFICATIONS
Table 1. OPERATING CONDITIONS
Symbol
Parameter
Min
2.3
−
Typ
3
Max
3.6
Unit
V
V
DD
Positive Supply
Ground
V
SS
0.0
+25
0.1
V
Temp
Temperature Range
0
+50
C
Table 2. ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Min
−
Max
+4
Unit
V
V
DD
Positive Supply
RF
Max RF Input RX1/RX2
Ground
−
+10
0.1
dBm
V
in
V
SS
0.0
−0.3
−40
V
in
Logical I/P Voltage
Storage Temperature
V
+ 0.3
V
DD
T
strg
+120
C
Idd (Supply Current)
Transmitting
Typ
20
7.5
75
−
Max
25
Unit
mA
mA
mA
Conditions
50% Duty Cycle
Receiving
Sniff Mode
Off
10
−
1% Sniff Cycle
RC OSC Off
500
nA
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. ELECTRICAL CHARACTERISTICS
Parameter
Digital Inputs
Min
Typ
Max
Unit
Comments
V
V
0.7 V
−
−
−
0.3 V
+1.0
−
V
V
ih
il
DD
−
−
DD
I
I
−
mA
mA
kW
ih
−1.0
−
−
il
2
I C Internal Pull-up
15
20
Digital Outputs
V
0.8 V
−
−
−
0.4
−1.0
−
V
oh
DD
V
ol
−
−
V
I
oh
−
mA
mA
kW
I
ol
2
+1.0
−
−
I C Internal Pull-up
Analog TX
15
20
Frequency Range
402
300
350
1
403.5
−
405
768
448
8
MHz
Targeted
Non-quick Start
Quick Start
−
Modulation
−
kbps
kbps
dBm
dB
Manchester-coded Data
NRZ Data
1
−
16
13
−
Max. Output Power
On/Off Ratio
11
−
12
70
75
Transmit
VCO Gain
−
−
MHz/V Kvco
http://onsemi.com
3