Series AME40-MAZ
40 Watt | AC-DC Converter
FEATURES:
• 4000VAC I/O isolation
•
•
•
•
Energy star compliant
RoHS compliant
Low Ripple and Noise
CE, cULus approvals
• Medical Switching power modules for PCB mounting
• Operating temperature: -40 to +85°C
• Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC
Models
Single output
CB
Efficiency
(%)
Output Current
Input Voltage
(VAC/Hz)
Input Voltage
Output Voltage
(V)
Model
max
(A)
8
(VDC)
AME40-3.3SMAZ
AME40-5SMAZ
AME40-12SMAZ
AME40-15SMAZ
AME40-24SMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
3.3
5
12
15
24
78
82
84
83
82
8
3.33
2.66
1.66
Models
Dual output
Output Current
Input Voltage
Input Voltage
(VDC)
Output Voltage
(V)
Efficiency
(%)
Model
max
(A)
(VAC/Hz)
AME40-5DMAZ
AME40-12DMAZ
AME40-15DMAZ
AME40-24DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-260/47-440
120-370
120-370
120-370
120-370
±5
±12
±15
±24
±4
80
85
82
77
±1.66
±1.33
±0.835
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
1000
530
Units
mA
mA
A
Current
25
50
Inrush current <2ms
A
Leakage current
External fuse
µA
A
150
Recommended slow blow type
No load; 115VAC
3.15
<0.5
Input dissipation
Start-up time
W
No load; 264VAC
<0.8
117
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Conditions
Typical
±2
±0.5
Maximum
Units
%
%
(LL-HL)
0-100% load single
0-100% load dual
±1
±2
±5
Load regulation
%
Cross regulation
25% load - 1st out, 100% load – 2nd out
Depending of the model
25% load Step
%
µF
% of Vout
mV p-p
ms
Maximum Capacitive load
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Minimum Load Current
470-23 000
±2
50
29
0
20MHz bandwidth
115VAC
% of Max
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only