36-100 Watts
AED Series
xppower.com
•
•
•
•
•
•
•
Low Profile
Single Outputs from 5 V to 48 V
Universal Input
Optional Floating Output
High Power Density
36, 45, 70 & 100 W Versions
Class II Insulation on 36 W Version
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
Isolation
• 85% typical at 230 VAC & 100% load
• 3000 VAC Input to Output,
1500 VAC Input to Ground.
Negative output is connected to ground.
For optional 500 VAC output to ground
isolation add suffix ‘-F’ to model number
• AED36: 1.00 A max
AED45: 1.20 A max
AED70: 1.85 A max
AED100: 2.00 A max
Switching Frequency
MTBF
• 60 kHz 10 kHz
Inrush Current
• AED36: 50 A max at 230 VAC
AED45: 100 A max at 230 VAC
AED70: 100 A max at 230 VAC
AED100: 100 A max at 230 VAC
• 100,000 Hrs to MIL-HDBK-217E
Environmental
Earth Leakage Current • AED36: Class II
AED45: 1.5 mA max
Operating Temperature • 0 ˚C to +65 ˚C
AED36, AED45 & AED70 derate
AED70: 1.5 mA max
AED100: 1.5 mA max
linearly from 100% load at +40 ˚C to
50% load at +55 ˚C,
AED100 derate linearly from
100% load at +40 ˚C to 0% at +65 ˚C
Power Factor
• Compliant with EN61000-3-2
Output
Storage Temperature
• -20 ˚C to +85 ˚C
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
• See tables
EMC & Safety
•
2%
Emissions
• CISPR22 Level B (EN55022)
FCC 20780 Level B
• No minimum load requirement
• AED36: 8 ms min at 115 VAC
AED45: 8 ms min at 115 VAC
AED70: 8 ms min at 115 VAC
AED100: 20 ms typical at 115 VAC
ESD Immunity
• EN61000-4-2,
8 kV air
4 kV contact
Perf Criteria A
Line Regulation
Load Regulation
Ripple & Noise
•
1%
Radiated Immunity
EFT/Burst
• EN61000-4-3, 3 V/m
Perf Criteria A
• See tables
• 1% pk-pk max, 20 MHz BW (see note 2)
• EN61000-4-4, level 2
Perf Criteria A
Overvoltage Protection • Typical 125% max
Overload Protection • 120-150% hiccup/trip & restart mode
with auto recovery
Short Circuit Protection • Continuous
Safety Approvals
• EN60950-1, UL60950-1,
CAN/CSA C22.2 No. 60950 cUL
Temperature
Coefficient
•
0.04%/˚C