82C54
CMOS Programmable Interval Timer
March 1997
Features
Description
• 8MHz to 12MHz Clock Input Frequency
The Intersil 82C54 is a high performance CMOS Program-
mable Interval Timer manufactured using an advanced 2
micron CMOS process.
• Compatible with NMOS 8254
- Enhanced Version of NMOS 8253
The 82C54 has three independently programmable and
functional 16-bit counters, each capable of handling clock
input frequencies of up to 8MHz (82C54) or 10MHz
(82C54-10) or 12MHz (82C54-12).
• Three Independent 16-Bit Counters
• Six Programmable Counter Modes
• Status Read Back Command
• Binary or BCD Counting
The high speed and industry standard configuration of the
82C54 make it compatible with the Intersil 80C86, 80C88,
and 80C286 CMOS microprocessors along with many other
industry standard processors. Six programmable timer
modes allow the 82C54 to be used as an event counter,
elapsed time indicator, programmable one-shot, and many
other applications. Static CMOS circuit design insures low
power operation.
• Fully TTL Compatible
• Single 5V Power Supply
• Low Power
- ICCSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10µA
- ICCOP . . . . . . . . . . . . . . . . . . . . . . . . . .10mA at 8MHz
• Operating Temperature Ranges
The Intersil advanced CMOS process results in a significant
reduction in power with performance equal to or greater than
existing equivalent products.
o
o
- C82C54 . . . . . . . . . . . . . . . . . . . . . . . . . .0 C to +70 C
o
o
- I82C54 . . . . . . . . . . . . . . . . . . . . . . . . . -40 C to +85 C
o
o
- M82C54 . . . . . . . . . . . . . . . . . . . . . . . -55 C to +125 C
Pinouts
82C54 (PDIP, CERDIP, SOIC)
82C54 (PLCC/CLCC)
TOP VIEW
TOP VIEW
D7
D6
1
2
3
4
5
6
7
8
9
24
VCC
23 WR
22
4
3
2
1
28 27 26
D5
RD
D4
D3
5
6
25 NC
21 CS
D4
24 CS
D3
20 A1
D2
19 A0
D2
7
23 A1
D1
18 CLK 2
17 OUT 2
16 GATE 2
D1
8
22 A0
D0
9
D0
21 CLK2
20 OUT 2
19 GATE 2
CLK 0
10
11
CLK 0
NC
15
OUT 0 10
GATE 0 11
GND 12
CLK 1
14 GATE 1
13 OUT 1
12 13 14 15 16 17 18
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
File Number 2970.1
http://www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 19994-1