Nexperia
74LVC1G58
Low-power configurable multiple function gate
8. Limiting values
Table 6. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
-0.5
-50
-0.5
-
Max
+6.5
-
Unit
V
VCC
IIK
supply voltage
input clamping current
input voltage
VI < 0 V
mA
V
VI
[1]
+6.5
±50
+6.5
+6.5
±50
100
-
IOK
VO
output clamping current
output voltage
VO > VCC or VO < 0 V
Active mode
mA
V
[1]
[1]
-0.5
-0.5
-
Power-down mode; VCC = 0 V
VO = 0 V to VCC
V
IO
output current
mA
mA
mA
°C
ICC
IGND
Tstg
Ptot
supply current
-
ground current
-100
-65
-
storage temperature
total power dissipation
+150
250
Tamb = -40 °C to +125 °C
[2]
mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SOT363-2 (TSSOP6) package: Ptot derates linearly with 3.7 mW/K above 83 °C.
For SOT457 (SC-74; TSOP6) package: Ptot derates linearly with 4.1 mW/K above 89 °C.
For SOT886 (XSON6) package: Ptot derates linearly with 3.3 mW/K above 74 °C.
For SOT1115 (XSON6) package: Ptot derates linearly with 3.2 mW/K above 71 °C.
For SOT1202 (XSON6) package: Ptot derates linearly with 3.3 mW/K above 74 °C.
9. Recommended operating conditions
Table 7. Recommended operating conditions
Symbol Parameter
Conditions
Min
1.65
0
Typ
Max
5.5
Unit
V
VCC
VI
supply voltage
input voltage
output voltage
-
-
-
-
-
5.5
V
VO
Active mode
0
VCC
5.5
V
Power-down mode; VCC = 0 V
0
V
Tamb
ambient temperature
-40
+125 °C
©
74LVC1G58
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2022. All rights reserved
Product data sheet
Rev. 11 — 1 February 2022
5 / 18