712-419
Self-Locking Composite Conduit Adapter for
Series 74 PEEK, PFA, ETFE, FEP or PTFE Tubing
Shielding Optional
712 F T 419 XM 19 12-20 K-1 A
K - Entry
Tubing shown for reference
only (See Note1)
1.250
(31.8)
Product Series
A Thread Typ.
(See Note 1)
Connector Designator
(A, F, H & U)
Tubing I.D.
J Typ
Angular Function
S - Straight
C
(see Note 2)
T = 45° Elbow
W = 90° Elbow
Anti-
Decoupling
Device
Sym S – Straight
Knurl or Flute Style Manufacurer's
Option, Typ.
Basic No.
Finish (Table III)
E
G
Shell Size (Table I) (See Note 1)
Dash No.(Table II)
F
Optional Length (See Note 3)
Symbol "S" only
Tubing Option (See Note 2)
K = PEEK (Omit for PFA, ETFE, FEP, or PTFE)
To accommodate EMI or Dacron overbraid
(Omit if Not Required)
H
Sym T
45°
Raised configuration
(Mfr's option)
Sym W
90°
Dash 1 configuration EMI or Dacron
over Braid (See P/N Development)
Add Letter for Optional Configuration
(See Detail A and Note 4)
Table I
E
F
G
H
Tubing
Shell Size
+.06 (1.5)
+.09 (2.3)
+.06 (1.5)
+.09 (2.3) Size Max.
A,F & H
G & U
08, 09
03, 10, 11
12, 13
–
.720 (18.3)
.750 (19.1)
.750 (19.1)
.760 (19.3)
.780 (19.8)
.790 (20.1)
.820 (20.8)
.860 (21.8)
.890 (22.6)
.920 (23.4)
.890 (22.6)
.950 (24.1)
1.020 (25.9)
1.050 (26.7)
1.070 (27.2)
1.080 (27.4)
1.110 (28.2)
1.150 (29.2)
1.180 (30.0)
1.210 (30.7)
.690 (17.5) 1.110 (28.2)
.750 (19.1) 1.160 (29.5)
.810 (20.6) 1.220 (31.0)
.880 (22.4) 1.290 (32.8)
.940 (23.9) 1.350 (34.3)
.970 (24.6) 1.380 (35.1)
1.060 (26.9) 1.470 (37.3)
1.130 (28.7) 1.540 (39.1)
1.190 (30.2) 1.730 (43.9)
1.340 (34.0) 1.820 (46.2)
09
12
16
20
24
28
32
32
40
40
08
10, 11
12, 13
14, 15
16, 17
18, 19
20
14, 15
16, 17
18, 19
20, 21
22, 23
24, 25, 61 22, 23
28
24, 25
Table II
Table III
Electroless Nickel
Cadmium Olive Drab Over Electroless
Nickel
No Plating - Black Material
No Plating - Base Material
Non-conductive
TABLE 2
Dash Conduit
No. I.D.
J Dia
Max
K
Entry
XM
XW
06 .188 (4.8) .540 (13.7) .120
09 .281 (7.1) .630 (16.0) .220
10 .312 (7.9) .690 (17.5) .240
12 .375 (9.5) .730 (18.5) .290
14 .437 (11.1) .800 (20.3) .340
(3.0)
(5.6)
(6.1)
(7.4)
(8.6)
XB
XO
16 .500 (12.7) .870 (22.1) .400 (10.2)
20 .625 (15.9) 1.000 (25.4) .520 (13.2)
24 .750 (19.1) 1.180 (30.0) .650 (16.5)
28 .875 (22.2) 1.320 (33.5) .780 (19.8)
32 1.000 (25.4) 1.470 (37.3) .900 (22.9)
40 1.250 (31.8) 1.760 (53.3) 1.080 (27.4)
48 1.500 (38.1) 2.130 (54.1) 1.320 (33.5)
Metric dimensions (mm) are in parentheses and are for reference only.
NOTES:
1. Convoluted tubing size, tubing to be ordered seperately (see Series 74
Catalog, Type A Tubing Section, Standard Pitch). Dash 1 configuration
accommodates Type B or D Tubing.
2. Different adapters are necessary to terminate PEEK tubing. Nominal I.D.
reduced by approximately .060 (use Suffix P) in P/N development.
3. Add optional length in 1/4 inch increments: 20 = 5.00 inches.
Omit for standard 1.250 length.
4. For permanant installation suse 3M Scotch Weld Tape after installing
tubing/shield (see Detail A).
© 2003 Glenair, Inc.
CAGE Codes 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com