Thermal-magnetic (TM and AS-line)  
AS168XDC2  
https://www.schurter.com /PG20  
Circuit Breaker for Equipment thermal-magnetic, 2 poles  
See below:  
Approvals and Compliances  
Description  
Applications  
- Thermal-magnetic circuit breaker  
- High short circuit performance  
- Availability of AC and DC in the same frame size  
- DIN-Rail Mounting  
- Industrial appliances  
References  
Last order possibility: 31.08.2018  
Last delivery date: 30.09.2018  
Weblinks  
pdf datasheet, html-datasheet, General Product Information, Distributor-  
Stock-Check, Detailed request for product, Product News  
Technical Data  
General data  
Tripping Type  
Positively trip free  
Rated Voltage DC  
IEC 240 V  
UL/CSA 240/360 V  
Actuation Type  
Manual ON/OFF  
Rated current  
0.5 - 50 A , see approbations  
Permissible wire cross section 1.5 - 25 mm² / 16 - 4 AWG  
Conditional short circuit capa- Icn: DC 240 V: 4.5 kA (no fuse)  
city IEC 60934  
Conditional short circuit capa- Icn: DC 240 V; DF/DG: 0.5A-40A: 10 kA  
Switched neutral  
Rated Voltage  
Rated current  
Function  
AC 277 V  
AC/DC 65 A  
city UL 1077  
(no fuse)  
The switched neutral closes with ma-  
nual closure of the poles and opens  
automatically with thermal magnetic  
tripping of the poles.  
Icn: DC 240 V; DH: 0.5A-40A: 5 kA (no  
fuse)  
Icn: DC 360 V; 0.5A-50A: 2 kA (no fuse)  
from front side IP 40 acc. to IEC 60529  
50Hz: > 2kV  
Degree of Protection  
Dielectric Strength  
Add-on modules  
Add-on modules  
Technical data for the additional module  
see separate data sheet  
Impulse 1.2/50 μs  
Vibration Resistance  
0.75 mm ꢀ 5 - 60 Hz  
acc. to IEC 60068-2-6, test Fc  
10 G ꢀ 60 - 500 Hz  
acc. to IEC 60068-2-6, test Fc  
250/440VAC > 5 MΩ  
30 G / 18ms  
Insulation Resistance  
Shock Resistance  
acc. to IEC 60068-2-27, test Ea  
Ambient temperature  
Weight  
-10°C to 55°C  
100 - 130g  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
1
Circuit Breakers  
 

与4420.0519相关器件

型号 品牌 获取价格 描述 数据表
4420.0530 SCHURTER

获取价格

Circuit Breaker for Equipment thermal-magnetic, 1 pole
4420.0542 SCHURTER

获取价格

Thermal Magnetic Circuit Breaker,
4420.0560 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 2 poles
4420.0569 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 3 poles
4420.0572 SCHURTER

获取价格

Thermal Magnetic Circuit Breaker,
4420.0595 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
4420.0596 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
4420.0597 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
4420.0605 SCHURTER

获取价格

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 2 poles
4420.0607 SCHURTER

获取价格

Thermal Magnetic Circuit Breaker,