VCPL (VCXO)
n
n
n
HIGH-FREQUENCY VCXO IN THRU-HOLE OR SMD METAL PACKAGE
PHASED-LOCK LOOP CIRCUIT (PLLC) USED
300 pS RMS MAXIMUM JITTER
STANDARD SPECIFICATIONS:
60.000 - 160.000 MHz
(Consult factory for specific available frequencies)
Frequency Range
Operating Temperature Range
0 - 70°C is standard, but can be extended to - 40 to +85°C
Frequency Stability over Operating
Temperature Range and Supply Voltage
Aging
Input Voltage
Output Logic Level
± 100 PPM is standard but ± 15, 25, 50 ppm also available.
3 PPM first year, 1 PPM per year thereafter at 25°C ± 5°C
5 V ± 5% Volt is standard but 3.3 V± 5% also available
HCMOS/TTL Compatible
Input Current (Icc) & Rise & Fall Time (Tr & Tf)
Output Load
Depends on frequency. See table on next page.
CMOS Load + 15 pF
Control Voltage Range
2.5V ± 2.0V for Vcc = 5.0V, 1.65V ± 1.32V for Vcc = 3.3V
Frequency Deviation (Pullability) over the
Control Voltage Range
Linearity
± 25, 50, 100, 150, 200, and 300 PPM available.
± 10%
Packaging
20 parts per tube, SMD: Tape and Reel TBD
PART NUMBERING GUIDE:
n
The Pletronics part number for a VCPL VCXO consists of the following 6 elements:
1. Model Number (Voltage):
2. Frequency Stability:
VCPL15: ±15 PPM
VCPL = 5V
3VCPL = 3.3V
VCPL25: ±25 PPM
VCPL50: ±50 PPM
VCPL100: ±100 PPM
3. Operating Temperature Range:
VCPL100A: 0 to +50°
VCPL100B: 0 to +70°C
VCPL100D:-20 to +75°C
VCPL100F:-40 to +85°C
VCPL100C: -10 to +70°C
VCPL100E: -30 to +75°C
4. Frequency Deviation over Control Voltage Range:
VCPL100AT: ±25 PPM
VCPL100AW: ±100 PPM
VCPL100AY: ±200 PPM
VCPL100AV: ±50 PPM
VCPL100AX: ±150 PPM
VCPL100AZ: ±300 PPM
5. Frequency of Operation in MHz
6. Optional Surface Mount Configuration - SMD
EXAMPLE: VCPL100CW-60.000 MHz, VCPL50DZ-60.000 MHz-SMD, 3VCPL15FT-60.000 MHz
When customer’s requirements are non-standard, a special engineering part number will be assigned.