MODEL: 27HU  
Head-mounted Two-wire Signal Conditioners  
27-UNIT  
RELATED PRODUCTS  
• USB interface Bell202 modem (model: COP-HU)  
Usable in ‘non-hazardous’ area only.  
• Hand-held communicator  
2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER  
(HART communication)  
• PC configurator software (model: 27HUCFG)  
Downloadable at M-System’s web site.  
Functions & Features  
• Universal input: DC mV, T/C, RTD and resistance  
• High accuracy  
GENERAL SPECIFICATIONS  
Construction: Sensor head-mounting  
Connection: M3 screw terminals (torque 0.5 N·m)  
Screw terminal: Nickel-plated brass  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output  
• HART communication  
• Intrinsically safe approval  
• Suitable for Functional Safety applications up to SIL2  
• Programming via hand-held communicator or via PC  
• A wide variety of T/C and RTD types  
• User’s temperature table can be used  
• Self diagnostics  
User-configurable items:  
• Input sensor type and numbers  
• Number of wires (RTD & resistance)  
• Input range (inverted range selectable)  
• Burnout  
• Ultra-low temp. drift option (20 ppm/°C typ.)  
• CE marking (conforms to ATEX and EMC)  
• Output limits (Upper / Lower)  
• Damping time (factory set to 0)  
• Cold junction compensation (T/C; internal or external  
sensor selectable)  
44 (1.73) DIA.  
• Linearization  
20.7  
(.81)  
• Sensor calibration  
• Output calibration  
mm (inch)  
• HART communication mode  
Refer to the HART setup manual or the PC configurator  
users manual for the detail.  
MODEL: 27HU–[1][2]  
HART COMMUNICATION  
Protocol: HART communication protocol  
HART address range: 0 – 15 (factory set to 0)  
Transmission speed: 1200 bps  
ORDERING INFORMATION  
• Code number: 27HU-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. 27HU-2/L)  
Digital current: Approx. 1 mAp-p when communicating  
Character format: 1 Start Bit, 8 Data Bits, 1 Odd Parity Bit,  
1 Stop Bit  
Use Ordering Information Sheet (No. ESU-7651). Factory  
standard setting will be used if not otherwise specified.  
Specify the country in which the product is to be used with  
the Safety Approval code 2.  
Distance: 1.5 km (0.9 miles)  
HART communication mode: Master-Slave Mode and Burst  
Mode (factory set to Master-Slave)  
HART network mode: Point-to-Point Mode and Multi-drop  
Mode; automatically set to Multi-drop Mode when the  
address is set to other than 0.  
[1] SAFETY APPROVAL  
0: None  
1: FM intrinsically safe  
2: ATEX intrinsic safety  
INPUT SPECIFICATIONS  
The input is factory set for use with K thermocouple, single  
input, 0 to 100°C, internal CJC sensor.  
See Table 1 for the available input type, the minimum span  
and the maximum range.  
[2] OPTIONS  
Temperature Drift  
Blank: Standard (temp. coefficient 0.015%/°C)  
/L: Ultra-low temperature drift  
DC mV (dual input available)  
Input resistance: ≥ 1 MΩ  
(temp. coefficient 0.002%/°C typ., 0.005%/°C max.)  
Thermocouple (dual input available)  
27HU SPECIFICATIONS  
ES-7651 Rev.17 Page 1/5  
http://www.m-system.co.jp/  

与27HU-0/L相关器件

型号 品牌 获取价格 描述 数据表
27HU-1 MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-1/L MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-2 MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-2/L MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000000 MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000000/S MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000001 MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000001/S MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000010 MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT
27HU-B-000010/S MSYSTEM

获取价格

Head-mounted Two-wire Signal Conditioners 27-UNIT