5秒后页面跳转
17RP-12M6-R PDF预览

17RP-12M6-R

更新时间: 2024-09-16 02:50:39
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 107K
描述
Rack-mounted Power Transducers 17-RACK

17RP-12M6-R 数据手册

 浏览型号17RP-12M6-R的Datasheet PDF文件第2页浏览型号17RP-12M6-R的Datasheet PDF文件第3页 
MODEL: 17RP  
Rack-mounted Power Transducers 17-RACK  
OUTPUT  
Voltage  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
VAR TRANSDUCER  
Functions & Features  
• Providing a DC output signal in proportion to AC reactive  
AUXILIARY POWER SUPPLY  
power  
DC Power  
• DC output containing little ripple is ideal for computer  
R: 24 V DC  
input  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
• "Time division multiplication" method accepts distorted  
waveforms  
GENERAL SPECIFICATIONS  
Construction: Rack-mounted; terminal access via screw  
terminals on the front and connector on the rear; terminal  
cover provided  
Typical Applications  
• Centralized monitoring and control of power management  
system in a manufacturing facility or building  
Connection  
Input: M3.5 screw terminals (torque 0.8 N·m)  
Output: Connector  
Auxiliary power: Supplied from connector  
Screw terminal: Nickel-plated steel  
Isolation: Voltage input to current input to output to  
auxiliary power  
Computation: Time division multiplication  
Overrange output: Approx. -10 to +120 %  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
MODEL: 17RP–1[1][2]6–R  
INPUT SPECIFICATIONS  
Frequency: 50 or 60 Hz  
ORDERING INFORMATION  
• Code number: 17RP-1[1][2]6-R  
• Voltage Input  
Operational range: 0 – 120 % of rating  
Overload capacity: 150 % of rating for 10 sec., 120 %  
continuous  
Specify a code from below for each [1] and [2].  
(e.g. 17RP-11P6-R)  
• Var range (e.g. LAG 1000 – LEAD 1000 var)  
• Current Input  
Operational range: 0 – 120 % of rating  
Overload capacity: 1000 % of rating for 3 sec., 200 % for 10  
sec., 120% continuous  
CONFIGURATION  
1: 3-phase / 3-wire  
How To Determine Var Range  
Calibration Range [var] = (Measuring Range) ÷  
((VT Ratio) × (CT Ratio))  
[1] INPUT (unbalanced load)  
(Voltage must be balanced.)  
1: 110 V / 5 A AC  
Check that the required calibration range is within the  
available range in the table.  
2: 110 V / 1 A AC  
[example]  
3: 220 V / 1 A AC  
3-phase / 3-wire, measuring range 75 kvar,  
VT 220 / 110 V, CT 250 / 5 A  
4: 220 V / 5 A AC  
(75 × 10 [var])÷((220 / 110) × (250 / 5))= 750 [var]  
3
I INPUT RANGE  
3-phase / 3-wire  
[2] OUTPUT SIGNAL POLARITY  
P: Negative in lag, positive in lead  
BURDEN (VA)  
VOLT. CURR.  
INPUT  
AVAILABLE  
RANGE  
M: Negative in lead, positive in lag  
STD.RANGE  
110V/1A  
110V/5A  
220V/1A  
220V/5A  
200 var  
0.2  
0.1/ph  
0.5/ph  
0.1/ph  
0.5/ph  
100  
500  
240 var  
1200 var  
480 var  
/phase  
1000 var  
4
00 var  
200  
0.4  
/phase  
2000 var  
1000  
2400 var  
http://www.m-system.co.jp/  
17RP SPECIFICATIONS  
ES-2967 Rev.0 Page 1/3  

与17RP-12M6-R相关器件

型号 品牌 获取价格 描述 数据表
17RP-12P6-R MSYSTEM

获取价格

Rack-mounted Power Transducers 17-RACK
17RP-13M6-R MSYSTEM

获取价格

Rack-mounted Power Transducers 17-RACK
17RP-13P6-R MSYSTEM

获取价格

Rack-mounted Power Transducers 17-RACK
17RP-14M6-R MSYSTEM

获取价格

Rack-mounted Power Transducers 17-RACK
17RP-14P6-R MSYSTEM

获取价格

Rack-mounted Power Transducers 17-RACK
17-RR-D1-F-02-10G AMPHENOL

获取价格

Connector Accessory
17-RR-D1-F-02-10K AMPHENOL

获取价格

Connector Accessory
17-RR-D1-F-04-10G AMPHENOL

获取价格

Connector Accessory
17-RR-D1-F-12-10G AMPHENOL

获取价格

Connector Accessory
17-RR-D1-F-14-10G AMPHENOL

获取价格

Connector Accessory