150ACP_S Series
150W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
150 Watt
The 150ACP_S series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installation
(35mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
High efficiency up to 87%
AC input selectable by switch
(115VAC/230VAC)
Withstand 300VAC surge input
for 5s
Over power protection (OPP)
Over load protection (OLP)
Short circuit protection (SCP)
Wide operating ambient
temperature (-20°C~65°C)
Suitable for critical
applications
Altitude up to 5000M
100% full load burn-in test
All using 105°C long life elect-
rolytic capacitors
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40°C MAX
Input voltage range
Input frequency
AC current
90~132VAC/176VAC~264VAC
47~63Hz
Free air convection
-20°C~+65°C
110VAC
220VAC
• 4.0A (max)
• 2.0A (max)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Power boost:
Inrush current
Cold start
220VAC
• 60A (typ)
-40°C ~+85°C
< 95%
Leakage current
Input—output: ≤0.25mA
Input—PG: ≤3.5mA
0.03%/°C MAX
+25°C >200,000 hours
150% of rated current
support
Parallel function:
Output specifications
Safety standards:
UL60950-1 2nd Ed; IEC 60950-
1:2005(2nd Ed); EN60950-1:2006
Item
Test conditions
Full load
Min
Typ
Max
1
Units
Output voltage
accuracy
%
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
Voltage adjustment
range
• 12V
• 24V
11.4
22.8
13.2
27.6
V
V
Dimensions:
Weight:
199*98.3*38mm
750g
Line regulation
Vin= min. to max. at
full load
0.5
%
Isolation specifications
Load regulation
Set-up time
0% to 100% load
1
%
s
Item
Test condition
Min
Typ
Max
Units
VAC
1.2
Withstand voltage*
• Primary-Sec.: 10mA
• Primary-PG: 10mA
• Secondary-PG: 10mA 500
3000
1500
Hold-up time
• @230VAC input
• @115VAC input
10
20
ms
ms
Overshoot and
undershoot
5
%
Isolation resistance
100
MΩ
Switching frequency
100
KHz
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Protection specifications
Over-load
protection
• 12V: 13.75~18.75A
• 24V: 6.88~9.38A
Protection type:
Constant power, auto recovery
Example:
150ACP_24S
Over-power
protection
165~225W
Protection type:
Constant power, auto recovery
150= 150Watt
AC= AC-DC
P= series
24= 24 Vout
S= single output
Note:
1. All parameters NOT specially mentioned are measured at rated input, rated load
and 25°C of ambient temperature.
Page 1 of 3
GAPTEC-Electronic GmbH & Co. KG
150ACP_S – Rev. 2017-1.1
sales@gaptec-electronic.com – www.gaptec-electronic.com
Specifications subject to change without notice.