150ACP_SC Series
150W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
150 Watt
High efficiency up to 87%
Universal AC input range
(85~264VAC)
Wide operating ambient
temperature (-20°C~65°C)
Operating altitude
up to 5000M
100% full load burn-in test
Easy assembling from top
side
PCB soldering side with
conformal coating
The 150ACP_SC series features standard rail mounting, energy efficien-
cy and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This conver-
ter offers a compact and light weight design with and standard rail ins-
tallation (35mm). Furthermore this series offers Easy Fuse Tripping due
and a built-in DC OK relay contact. The converter can be installed on
TS-35/7.5 or TS-35/15.
Built-in Active PFC function,
PF>0.95
Over power protection (OPP)
Over load protection (OLP)
Short circuit protection (SCP)
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40°C MAX
Input voltage range
Input frequency
Power factor
85~264VAC
47~63Hz
115VAC
• 0.98 (typ)
230VAC
Free air convection
-20°C~+65°C
• 0.95 (typ)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Power boost:
AC current
115VAC
• 1.7A (max)
230VAC
• 0.8A (max)
-20°C ~+85°C
< 95%
Inrush current
Leakage current
Cold start
115VAC
• 30A (typ)
230VAC
• 50A (typ)
0.03%/°C MAX
Input—output: ≤0.25mA
Input—PG: ≤3.5mA
+25°C >200,000 hours
150% of rated current
support
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd
Ed); EN60950-1:2006
Parallel function:
Output specifications
Safety standards:
Item
Test conditions
Full load
Min Typ
Max
1
Units
Output voltage
accuracy
%
%
%
%
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
Voltage adjustment
range
10
0.5
1
Dimensions:
Weight:
199*99*38mm
750g
Line regulation
Vin= min. to max. at
full load
Isolation specifications
Load regulation
Set-up time
0% to 100% load
Item
Test condition
Min
Typ
Max
Units
VAC
• @230VAC input
• @115VAC input
2
4
s
s
Withstand voltage*
• Primary-Sec.: 10mA
• Primary-PG: 10mA
• Secondary-PG: 10mA
3000
1500
500
Hold-up time
15
5
ms
%
Overshoot and
undershoot
Isolation resistance
100
MΩ
Switching fre-
quency
100
KHz
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Protection specifications
Over-load
protection
105%~150% of rated output current, hiccup mode, auto
recovery
Example:
150ACP_24SC
Over-power
protection
105%~150% of rated output current, hiccup mode, auto
recovery
150 = 150Watt
AC = AC-DC
P = series
Note:
24 = 24 Vout
1. All parameters NOT specially mentioned are measured at rated input, rated
load and 25°C of ambient temperature.
S = single output
C = PFC (Power Factor Correction)
Page 1 of 3
150ACP_SC – Rev. 2020-1.2
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG