Multilayer Ceramic Capacitors
Approval Sheet
5. EXTERNAL DIMENSIONS
Size
Inch (mm)
L (mm)
W (mm)
T (mm)/Symbol
Remark
MB (mm)
L
0.25
+0.05/-0.10
0402 (1005)
1.00±0.05
1.60±0.10
0.50±0.05
0.80±0.10
0.50±0.05
0.80±0.07
N
S
X
#
T
0603(1608)
0805 (2012)
0.40±0.15
0.50±0.20
1.60
+0.15/-0.10
0.80
+0.15/-0.10
0.80
+0.15/-0.10
0.60±0.10
W
A
B
D
I
MB
MB
2.00±0.15
2.00±0.20
3.20±0.15
3.20±0.20
1.25±0.10
1.25±0.20
1.60±0.15
1.60±0.20
0.80±0.10
1.25±0.10
1.25±0.20
0.80±0.10
0.95±0.10
1.25±0.10
1.60±0.20
#
#
Fig. 1 The outline of MLCC
B
C
D
G
P
C
D
G
K
#
#
#
#
#
#
#
#
0.60±0.20
(0.5±0.25)*
1206 (3216)
1210 (3225)
3.20+0.3/-0.1 1.60+0.3/-0.1 1.60+0.3/-0.1
0.95±0.10
3.20±0.30
2.50±0.20
2.50±0.30
1.25±0.10
1.60±0.20
2.00±0.20
2.50±0.30
0.75±0.25
3.20±0.40
M
#
3.20±0.60**
2.50±0.50** 2.50±0.50**
1.25±0.10
D
G
K
#
#
#
#
#
#
#
#
1808 (4520) 4.50+0.5/-0.3
2.03±0.25
1.60±0.20
2.00±0.20
1.25±0.10
1.60±0.20
2.00±0.20
2.50±0.30
2.80±0.30
0.50±0.25
0.50±0.25
D
G
K
3.20±0.30
3.20±0.40
1812 (4532) 4.50+0.5/-0.3
M
U
# Reflow soldering only is recommended.
* For 1206_1000V ~3000V products.
** For 1210(100V)/Cap>1µF or 1210(250V)/Cap>0.47µF or 1210(400V~630V)/Cap>0.22µF
6. GENERAL ELECTRICAL DATA
Dielectric
Size
NP0
X7R
0402, 0603, 0805, 1206, 1210, 1808, 1812
Capacitance*
0.1pF to 0.022µF
Cap≤5pF: C (±0.25pF)
100pF to 1.0µF
#1
5pF<Cap<10pF: D (±0.5pF)
Capacitance tolerance***
J (±5%) , K (±10%), M (±20%)
Cap≥10pF: F (±1%), G (±2%), J (±5%),K (±10%)
Rated voltage (WVDC)
Q/DF*
200V to 4000V
Cap<30pF: Q≥400+20C
Cap≥30pF: Q≥1000
DF≤2.5%
Ur=200~630V: ≥10GΩ or RxC≥100Ω-F whichever is smaller
Insulation resistance at Ur**
Dielectric strength
Ur=1000~3000V: ≥10GΩ
200~300V: ≥2 x WVDC
400V~450V: ≥1.2 x WVDC
500~999V: ≥1.5 x WVDC
1000~3000V: ≥1.2 x WVDC
4000: ≥1.1 x WVDC
Operating temperature
Capacitance characteristic
Termination
-55 to +125°C
±30ppm
±15%
Ni/Sn (lead-free termination)
#1: X7R products can provide optional J(±5%) capacitance tolerance.
* Measured at the condition of 30~70% related humidity.
NP0: Apply 1.0±0.2Vrms, 1.0MHz±10% for Cap≤1000pF and 1.0±0.2Vrms, 1.0kHz±10% for Cap>1000pF, 25°C at ambient temperature
X7R, X5R: Apply 1.0±0.2Vrms, 1.0kHz±10%, at 25°C am bient temperature.
** Preconditioning for Class II MLCC: Perform a heat treatment at 150±10°C for 1 hour, then leave in a mbient condition for 24±2 hours
before measurement.
Page 3 of 12
ASC_Middle & High Voltage