General Purpose Relays
SCHRACK
Power Relay 430 3 mm
n
n
n
n
n
n
n
n
n
1 pole 16 A, 1 NO contact
Safety mains isolation
Contact gap > 3 mm
DC- and AC-coil
4 kV / 8 mm coil-contact, reinforced insulation (VDE 0700)
PCB mounting or quick connect terminals
Mounting brackets or snap mounting
Version with arc blow magnet for high DC-loads
Product in accordance to IEC60335-1
F0256-B
Applications
Domestic appliances, industrial appliances, industrial controls
Approvals
V
REG.-Nr. C820,
Z
E214024
Technical data of approved types on request
Contact data
Contact configuration
1NO
bifurcated contact
full disconnection
250 / 400 VAC
16 A
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Contact gap
Rated frequency of operation with / without load
4000 VA
25 A
AgCu3, AgCdO
> 3 mm
15 / 300 min-1
Contact ratings
Type
Contact
Load
Ambient
temp. [°C]
Cycles
IEC 61810
0430 .4 .. 0
0430 .4 .. 1
NO
NO
16 A, 250 VAC, cosϕ=1
16 A, 250 VAC, cosϕ=1
70°C
70°C
50x103
50x103
Coil data
Rated coil voltage range DC coil
AC coil
6...110 VDC
6...240 VAC
2
Operative range to IEC 61810
Coil versions, DC-coil
Coil
Rated
voltage
VDC
12
Operate
voltage
VDC
Release
voltage
VDC
0.6
Coil
resistance
Ohm
145+10%
580+10%
2200+10%
13000+10%
Rated coil
power
mW
code
09
10
11
13
7.8
993
24
15.6
1.2
993
1047
931
48
31.2
2.4
5.5
110
71.5
Coil versions, AC-coil 50Hz
Coil
Rated
voltage
VAC
24
Operate
voltage
VAC
18
Release
voltage
VAC
Coil
resistance
Ohm
145+10%
950+10%
3100+10%
11400+10%
13000+10%
Rated coil
power
VA
code
23
25
26
27
28
3.6
1.8
60
45
83
9.0
1.8
110
16.0
1.8
230
175
185
35.0
1.8
240
36.0
1.8
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.