XS Inductive Sensors
NAMUR, AC and DC
www.SquareD.com
FOR CURRENT INFORMATION
W
D
D
W
W
D
D
W
XSC
XSBN1•
XSBN2•
XSD
Cylindrical type b
Nominal
Sensinga
Distance
Max. apparent
sensing
capacitancea
Barrel
Diameter
Operating
Frequency
Voltage
range
Max. line
resistance
Max. apparent
sensing inductancea
Dimensions
a, b, c
Catalog
Number
Price
Nickel plated brass case—Shielded, 2 m (6.6') cable
4 mm
0.8 mm
0.8 mm
1 mm
1500 Hz
1500 Hz
1500 Hz
1000 Hz
7–12 Vdc
7–12 Vdc
7–12 Vdc
7–12 Vdc
50 ohms
50 ohms
50 ohms
50 ohms
280 nF
280 nF
280 nF
280 nF
220 micro H
220 micro H
220 micro H
220 micro H
30, ..., ...
30, 30, ...
40, ..., ...
27, ..., ...
XSLN08122
XSMN08122
XSLN01122
XSAN01122
$42.00
42.00
36.00
39.00
5 mm
6.5 mm
8 mm
1 mm
Plastic case—Shielded, 2 m (6.6') cable
8 mm
12 mm
18 mm
30 mm
1.5 mm
1000 Hz
800 Hz
500 Hz
300 Hz
7–12 Vdc
7–12 Vdc
7–12 Vdc
7–12 Vdc
50 ohms
50 ohms
50 ohms
50 ohms
280 nF
280 nF
280 nF
280 nF
220 micro H
220 micro H
220 micro H
220 micro H
27, ..., ...
37, ..., ...
44, ..., ...
42, ..., ...
XSPN01122
XSPN02122
XSPN05122
XSPN10122
39.00
30.10
35.60
46.50
2 mm
5 mm
10 mm
Plastic case—Non-shielded, 2 m (6.6') cable
12 mm
18 mm
30 mm
4 mm
400 Hz
300 Hz
200 Hz
7–12 Vdc
7–12 Vdc
7–12 Vdc
50 ohms
50 ohms
50 ohms
280 nF
280 nF
280 nF
220 micro H
220 micro H
220 micro H
37, ..., ...
44, ..., ...
44, ..., ...
XSPN04122
XSPN08122
XSPN15122
30.80
36.00
46.50
8 mm
15 mm
Plastic block type b
Max. apparent
sensing
capacitancea
Enclosure
Style
Nominal
Sensing Distance
Operating
Frequency
Voltage
range
Max. line
resistance
Apparent sensing
inductancea
Dimensions
H x W x D
Catalog
Number
Price
Shielded, terminal connections
Limit switch style
15 mm
100 Hz
7–12 Vdc
50 ohms
280 nF
220 micro H
115, 40, 40
XSCN151229
$ 52.00
Non-shielded, terminal connections
Compact rectangular
13 mm
25 mm
40 mm
250 Hz
250 Hz
25 Hz
7–12 Vdc
7–12 Vdc
7–12 Vdc
50 ohms
50 ohms
50 ohms
280 nF
280 nF
280 nF
220 micro H
220 micro H
220 micro H
77, 34, 33
50, 50, 41
101, 82, 40
XSBN10122
XSBN25122
XSDN501229
46.50
75.00
111.00
Block style
Block style—extended range
a Consider for intrinsically safe systems.
b For use with intrinsically safe barrier relay when used in hazardous locations. See Relay Section page 21-17.
Dimensions:
a = overall length (mm)
b = threaded section (mm)
b
c
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-75
Application Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-78
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-69
c = for non-shielded sensors
a
For additional information, reference Catalog #9006CT2000 or D-FAX™ #1582.
To convert mm to inches, divide by 25.4
Discount
Schedule
© 2002 Schneider Electric
all rights reserved
DS2