16 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
Frequency specifications1, 2  
Accuracy ± (% of reading +  
counts of least significant digit)  
Range  
Resolution  
Minimum input frequency  
99.999 Hz  
999.99 Hz  
9.9999 kHz  
99.999 kHz  
999.99 kHz  
> 1 MHz  
0.001 Hz  
0.01 Hz  
0.1 Hz  
0.02 + 5  
0.005 + 5  
0.005 + 5  
0.5 Hz  
1 Hz  
0.005 + 5  
0.01 kHz  
0.1 kHz  
0.005 + 5  
0.005 + 5 @ < 1 MHz  
1. Overload protection: 1000 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency).  
2. The frequency measurement is susceptible to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise pickup is criti-  
cal for minimizing measurement errors. Turning on the low pass filter may help you to filter out the noise and achieve a stable reading.  
Duty Cycle3  
Mode  
Range  
99.99%  
99.99%  
Accuracy at full scale  
0.3 % per kHz + 0.3 %  
0.3 % per kHz + 0.3 %  
DC coupling  
AC coupling  
3. Notes for duty cycle specifications:  
- The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range. For AC couplings, the duty cycle  
range can be measured within the range of 10% to 90% for signal frequencies > 20 Hz.  
- The range of the duty cycle is determined by the frequency of the signal: {10 μs × frequency × 100%} to {[1 – (10 μs × frequency)] × 100%}.  
- The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.  
Pulse Width4  
Range  
Resolution  
0.01 ms  
0.1 ms  
Accuracy at full scale  
999.99 ms  
2000.0 ms  
(duty cycle accuracy/frequency) + 0.01 ms  
(duty cycle accuracy/frequency) + 0.1 ms  
4. Notes for pulse width specifications:  
- The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range.  
- The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.  

U1273A 替代型号

型号 品牌 替代类型 描述 数据表
U1273AX KEYSIGHT

完全替代

U1270 Series Handheld Digital Multimeters

与U1273A相关器件

型号 品牌 获取价格 描述 数据表
U1273AX KEYSIGHT

获取价格

U1270 Series Handheld Digital Multimeters
U-127U ETC

获取价格

AUDIO
U12C05 MOSPEC

获取价格

POWER RECTIFIERS(12A,50-200V)
U12C05_05 MOSPEC

获取价格

Switchmode Dual Ultrafast Power Rectifiers
U12C10 MOSPEC

获取价格

POWER RECTIFIERS(12A,50-200V)
U12C15 MOSPEC

获取价格

POWER RECTIFIERS(12A,50-200V)
U12C20 MOSPEC

获取价格

POWER RECTIFIERS(12A,50-200V)
U12C20A THINKISEMI

获取价格

12 Ampere Common Anode Ultra Fast Recovery Rectifier Diodes
U12C20A_18 THINKISEMI

获取价格

12.0 Ampere Dual Common Anode Ultra Fast Recovery Rectifiers
U12C20C THINKISEMI

获取价格

12 Ampere Common Cathode Ultra Fast Recovery Rectifiers