APPLICABLE STANDARD
Operating
Storage
-40C to +105C (Note 1)
-55C to +85C (Note 2)
Temperature Range
Temperature Range
―
Rating
Voltage
―
―
―
―
Current
Applicable Cable
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
General Examination
Marking
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
MECHANICAL CHARACTERISTICS
500 times insertions and extractions.
No damage, crack and looseness of parts.
X
X
-
-
Mechanical Operation
1) No electrical discontinuity of 10 s.
Frequency : 10 to 55 hz, singe amplitude 0.75 mm,
at 2 h, for 3 axial directions.
(refer to an attached figure)
JIS E 4031 category 1 class B
frequency:5~150H
Vibration
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 10 s.
Vibration
2) No damage, crack and looseness of parts.
X
-
(Railway Random Vibration
Test)
condition m/s2
asd level(m/s2)2/Hz
7.90
1.857
3 axial directions, 5 h each.
490 m/s2 duration of pulse 11 ms at 3 times in 3 both
axial directions. Half-sine wave.
1) No electrical discontinuity of 10 s.
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 10 s.
2) No damage, crack and looseness of parts.
X
X
-
-
Shock
JIS E 4031 category 1 class B
Peak acceleration m/s2 nominal time ms
Shock (Railway)
50
30
3 both axial directions, 3 times each.
ENVIRONMENTAL CHARACTERISTICS
Temperature -40 → 15 to 35 → 105 → 15 to 35 C
No damage, crack and looseness of parts.
X
X
X
X
-
-
-
-
Rapid Change Of Temperature
Heat Resistance
Cold Resistance
Humidity
time 30 → 2 to 3 → 30 → 2 to 3 min. under 5 cycles.
Exposed at 105 2 C, 96 h.
1) Insulation resistance : 1000 M min.
2) No damage, crack and looseness of parts.
1) Insulation resistance : 1000 M min.
2) No damage, crack and looseness of parts.
1) Insulation resistance : 1000 M min.(at dry)
2) No damage, crack and looseness of parts.
No heavy corrosin ruin the function.
combining the applicable connectors.
Exposed at -55 3 C, 96 h.
combining the applicable connectors.
Exposed at 60 2 C, 95 3 %, 96 h.
combining the applicable connectors.
Exposed in H2S 0.1 0.02 ppm, SO2 0.5 0.1 ppm, 25
2 C, 75 3 %, 96 h.
X
X
-
-
Mixed Flowing Gus
Combining the applicable connectors.
Exposed in 5 % salt water spray for 48 h.
Combining the applicable connectors.
Corrosion Salt Mist
No heavy corrosin ruin the function.
Note 1 ① The product performance is guaranteed only in the temperature adequate people’s activities.
② Include temperature rise caused by current-carrying.
③ Specifications for assembled item with applicable housing.
Note 2 Packing materials are not included.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NM.NISHIMATSU
NM.NISHIMATSU
MO.SHIMOYAMA
MO.SHIMOYAMA
16.05.11
16.05.11
16.05.10
16.05.10
Above spesification shows the values in assembled condition with applicable crimp contacts.
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-128603-02-00
PART NO.
CODE NO.
TJ50A-41S-U-CV1(02)
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL236-3119-6-02
FORM HD0011-2-1