APPLICABLE STANDARD
Operating temperature
ISO/IEC 11801 CLASS D CATEGORY 5
Storage temperature
-10 to +60 C (Note 2)
-40 to +85 C (Note 1)
range
range
RATING
Operating humidity
range
Voltage
Current
100 V AC, 100 V DC
4 A / pin (Note 4)
10 to 90 %
Applicable cable
Cable OD Ø 8.4 0.4
SPECIFICATIONS
ITEM
PROCEDURE
REQUIREMENTS
QT AT
CONSTRUCTION
General examination
Marking
X
X
X
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
ELECTRICAL CHARACTERISTICS
Contact resistance
100 mA MAX. (DC or 1000 Hz)
1) Contact : 10 m MAX. (Note 3)
2) Shielding : 50 m MAX. (Note 3)
5000 M MIN.
X
X
-
-
Insulation resistance
Voltage proof
500 V DC.
1500 V AC for 1 min.
No flashover or breakdown.
・Distance between two female contacts.
・Distance between female contact and the
J-Shield plate.
X
-
MECHANICAL CHARACTERISTICS
Contact insertion, release and Measured by applicable contact.
extraction force
Insertion force : 12 N MAX.
X
X
-
-
Extraction force : 0.5 N MIN.
Engaging and separating
forces
Measured by applicable connector.
Engaging force : 40 N MAX. (Typical:16.7N)
Separating force : 10 N MIN. (Typical:13.8N)
Mechanical operation
500 times insertions and extractions.
1) Contact : 25 m MAX. (Note 3)
X
X
-
-
2) Shielding : 70 m MAX. (Note 3)
3) No damage, crack and looseness of parts.
1) No electrical discontinuity of 10 s.
Frequency 10 to 55 Hz single amplitude 0.75 mm, 3 axial
directions, 2 h each.
Vibration (sinusoidal)
Vibration
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 10 s.
JIS E 4031 CATEGORY 1 CLASS B
2) No damage, crack and looseness of parts.
(Railway random vibration test) Frequency : 5 to 150 Hz
Excitation condition RMS : 7.90 m/s2
X
-
ASD level : 1.857 (m/s2)2/Hz
3 axial directions, 5 h each.
1) No electrical discontinuity of 10 s.
Shock
Acceleration 490 m/s2, duration of pulse 11 ms, for 3 times in
3 both axial directions. (half-sine wave)
JIS E 4031 CATEGORY 1 CLASS B
Peak acceleration : 50 m/s2
X
X
-
-
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 10 s.
Shock (Railway)
2) No damage, crack and looseness of parts.
Nominal time : 30 ms
3 both axial directions, 3 times each.
ENVIRONMENTAL CHARACTERISTICS
Rapid change of temperature Temperature : -40 → 15 to 35 → 125 → 15 to 35 c
1) Contact : 25 m MAX. (Note 3)
Time
:
30 → 2 to 3
→
30 → 2 to 3 min. 2) Shielding : 70 m MAX. (Note 3)
Under 5 cycles.
3) No damage, crack and looseness of parts.
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
TU.TANIGUCHI
TU.TANIGUCHI
KN.ICHIKAWA
KN.ICHIKAWA
20201015
20201015
20201015
20201015
This specification sheet shows the performance with incorporated applicable crimp
contacts and compatible connector.
Unless otherwise specified, refer to IEC 60512.
Note QT: Qualification Test AT: Assurance Test X: Applicable Test
DRAWING NO.
ELC-128637-00-01
TJ50L(1)-4P-C(8.4)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1/3
0
△
CL236-3228-1-00
FORM HD0011-2-1