TH8056
Enhanced Single Wire CAN Transceiver
Features
Fully compliant to GMW3089 V2.4 and J2411 Single Wire CAN specification for Class B
in-vehicle communications
Only 60 µA worst case sleep mode current independent from CAN voltage range
Operating voltage range 5V to 26.5V
Up to 40 kbps bus speed
Up to 100 kbps high-speed transmission mode
Logic inputs compatible with 3.3V and 5V supply systems
Control pin for external voltage regulators
Low RFI due to output wave shaping in normal and high voltage wake up mode
Fully integrated receiver filter
Bus terminals proof against short-circuits and transients in automotive environment
Loss of ground protection, very low leakage current (typ. 20µA at 26.5V and 125°C)
Protection against load dump, jump start
Thermal overload and short circuit protection
Under voltage lockout
Bus dominant time-out feature
Pb-Free 14-pin thermally enhanced and 8-pin SOIC package
Ordering Information
Part No.
Temperature Range
Package
Revision
TH8056 KDC A
TH8056 KDC A8
-40 to 125 °C
-40 to 125 °C
SOIC14
SOIC8
A
A
General Description
The TH8056 is a physical layer device for a single wire data link capable of operating with various CSMA/CR protocols
such as the Bosch Controller Area Network (CAN) version 2.0. This serial data link network is intended for use in
applications where a high data rate is not required and a lower data rate can achieve cost reductions in both the physical
media components and the microprocessor and/or dedicated logic devices that use the network.
The network shall be able to operate in either the normal data rate mode or the high-speed data download mode for
assembly line and service data transfer operations. The high-speed mode is only intended to be operational when the
bus is attached to an off-board service node. This node shall provide temporary bus electrical loads which facilitate
higher speed operation.
The bit rate for normal communications is typically 33.33kbit/s, for high-speed transmissions as described above a typical
bit rate of 83.33kbit/s is recommended. The TH8056 is designed in accordance with the Single Wire CAN Physical Layer
Specification GMW3089 V2.4 and supports many additional features like under-voltage lock-out, time-out for faulty
blocked input signals, output blanking time in case of bus ringing and a very low sleep mode current.
TH8056 – Datasheet
3901008056
Page 1 of 26
March 2007
Rev 012