TE60
60W Single Output External Power
Test & Measurement/Industrial Series
Features
.
Meets DoE Efficiency Level VI Requirements
.
.
No load input power
Average Efficiency
.
.
.
.
Up to 60W of AC-DC Power
Universal Input 90-264Vac Input Range
IP22 Rated Enclosure
Meets “Heavy Industrial” Levels of EN61000
EMC Requirements
.
.
Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin
Approved to EN/IEC/UL60950-1, 2nd Edition,
Am. 2
.
.
.
.
E-cap life of >8 years
>900,000 hours MTBF
3 Year Warranty
IP22 Rated Enclosure
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial
levels of various EN61000-4-x standards for EMC. The TE60A series models also meet Class B conducted and radiated
EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment
and other industrial applications.
Model Selection
Output Cable
& Connector
Input
Configuration
Model
Number
Output
Current
7.00A
Output
Power
35W
Ripple &
Noise¹
75mV pk-pk
Line
Regulation
±1%
Load
Regulation
±5%
Volts
5.0V
TE60A0551F01
6 pin Molex Type2
TE60A0903F01
TE60A1203F01
TE60A1503F01
TE60A1803F01
TE60A2403F01
TE60A4803F01
TE60A0551N01
TE60A0903N01
TE60A1203N01
TE60A1503N01
TE60A1803N01
TE60A2403N01
TE60A4803N01
TE60A0551Q01
TE60A0903Q01
TE60A1203Q01
TE60A1503Q01
TE60A1803Q01
TE60A2403Q01
TE60A4803Q01
9.0V
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
7.00A
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
7.00A
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
54W
60W
60W
60W
60W
60W
35W
54W
60W
60W
60W
60W
60W
60W
54W
60W
60W
60W
60W
60W
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
Class I Desktop,
IEC60320 C14
Receptacle
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
6 pin Molex Type2
9.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
Class II Desktop,
IEC60320 C8
Receptacle
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
6 pin Molex Type2
9.0V
12.0V
15.0V
18.0V
24.0V
48.0V
Class II Desktop,
IEC60320 C18
Receptacle
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
Notes:
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. For 5V and 6V models, values listed
are typical, 100mV pk-pk maximum.
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01).
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE60 Rev 2.5
13-JAN-16
1