150W Single Output with PFC Function
SPV-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Output voltage programmable from 20~110% by 1~5.5VDC external
control signal
Built-in remote ON-OFF control
Fixed switching frequency at 100KHz
3 years warranty
SPECIFICATION
MODEL
SPV-150-12
SPV-150-24
SPV-150-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
12.5A
0 ~ 12.5A
150W
6.25A
3.125A
0 ~ 3.125A
150W
0 ~ 6.25A
150W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
150mVp-p
240mVp-p
41 ~ 52.8V
1.0%
OUTPUT
10.8 ~ 13.2V
20 ~ 26.4V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.3%
0.2%
0.5%
0.2%
0.5%
0.5%
800ms, 50ms/230VAC
2500ms, 50ms/115VAC at full load
16ms/230VAC
Note.5 88 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.94/230VAC
82%
PF>0.98/115VAC at full load
83%
INPUT
83%
2.5A/115VAC
1.25A/230VAC
40A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
20A/115VAC
<1mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
57.6 ~ 67.2V
OVERLOAD
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
80 (TSW1 : detect on heatsink of power transistor)
27.6 ~ 32.4V
PROTECTION OVER VOLTAGE
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
4 ~ 10VDC power off, <0 ~ 0.8VDC power on
REMOTE CONTROL
OUTPUT VOLTAGE TRIM
WORKING TEMP.
FUNCTION
9.6 ~ 52.8V
2.4 ~ 13.2V
4.8 ~ 26.4V
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
207K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
215*115*50mm (L*W*H)
1.1Kg; 12pcs/14Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SPV-150-SPEC 2010-10-18