sp-500 ꢀerieꢀ
500W Single Output with PFC Function
ꢳꢈꢅꢉꢔꢆꢈꢊꢁꢪ
ꢱꢑꢏꢭꢈꢆꢊꢅꢃꢁꢂꢙꢁꢏꢑꢄꢔꢉꢁꢲꢁꢳꢔꢃꢃꢁꢆꢅꢑꢥꢈ
ꢴꢔꢏꢃꢉꢧꢏꢑꢁꢅꢎꢉꢏꢭꢈꢁꢯꢳꢙꢁꢜꢔꢑꢎꢉꢏꢒꢑꢚꢁꢯꢳꢵꢗꢀꢶꢛ
ꢯꢆꢒꢉꢈꢎꢉꢏꢒꢑꢊꢪꢷꢤꢒꢆꢉꢁꢎꢏꢆꢎꢔꢏꢉꢲꢌꢭꢈꢆꢁꢃꢒꢅꢓꢲꢌꢭꢈꢆꢁꢭꢒꢃꢉꢅꢥꢈꢲꢌꢭꢈꢆꢁꢉꢈꢇꢄꢈꢆꢅꢉꢔꢆꢈ
ꢳꢒꢆꢎꢈꢓꢁꢅꢏꢆꢁꢎꢒꢒꢃꢏꢑꢥꢁꢝꢐꢁꢝꢔꢏꢃꢉꢧꢏꢑꢁꢮꢙꢁꢜꢅꢑ
ꢴꢔꢏꢃꢉꢧꢏꢑꢁꢎꢒꢒꢃꢏꢑꢥꢁꢳꢅꢑꢁꢌꢋꢧꢌꢳꢳꢁꢎꢒꢑꢉꢆꢒꢃ
ꢴꢔꢏꢃꢉꢧꢏꢑꢁꢆꢈꢇꢒꢉꢈꢁꢌꢋꢧꢌꢳꢳꢁꢎꢒꢑꢉꢆꢒꢃ
ꢴꢔꢏꢃꢉꢧꢏꢑꢁꢆꢈꢇꢒꢉꢈꢁꢊꢈꢑꢊꢈꢁꢜꢔꢑꢎꢉꢏꢒꢑ
ꢳꢏꢸꢈꢓꢁꢊꢣꢏꢉꢎꢤꢏꢑꢥꢁꢜꢆꢈꢫꢔꢈꢑꢎꢐꢁꢅꢉꢁ��ꢗꢹꢡꢢ
ꢖꢁꢐꢈꢅꢆꢊꢁꢣꢅꢆꢆꢅꢑꢉꢐ
SPECIFICATION
MODEL
SP-500-12
SP-500-13.5
SP-500-15
SP-500-24
SP-500-27
SP-500-48
DC�VOLTAGE
12V
13.5V
36A
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
40A
32A
20A
18A
10A
0�~�40A
480W
0�~�36A
486W
0�~�32A
480W
0�~�20A
480W
0�~�18A
486W
200mVp-p
24�~�30V
1.0%
0�~�10A
480W
300mVp-p
41�~�56V
1.0%
RIPPLE�&�NOISE�(max.) Note.2 240mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 1.0%
240mVp-p
12�~�15V
1.0%
240mVp-p
13.5�~�18V
1.0%
240mVp-p
20�~�26.4V
1.0%
OUTPUT
10�~�13.2V
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1500ms,�50ms�at�full�load
24ms�at�full�load
VOLTAGE�RANGE
Note.5 88�~�264VAC����������124�~�370VDC
47�~�63Hz
FREQUENCY RANGE
POWER�FACTOR (Typ.)
EFFICIENCY(Typ.)
PF>0.95/230VAC����������PF>0.95/115VAC�at�full�load
84% 84% 83%
INPUT
85.5%
86.5%
87%
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
7A/115VAC���������3.5A/230VAC
18A/115VAC����������36A/230VAC
<3.5mA/240VAC
105�~�135% rated�output�power
OVER�LOAD
Protection�type�:�Fold�back�current�limiting,�recovers�automatically�after�fault�condition�is�removed
13.8�~�16.2V 15.5�~�18.2V 18�~�21V 27.6�~�32.4V 31�~�36.5V
57.6�~�67.2V
PROTECTION
OVER�VOLTAGE
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
RTH1�or�RTH2 50 FAN�ON, 45 FAN�OFF, 70 output�shutdown
FAN�CONTROL,�O.T.P.
FUNCTION REMOTE�CONTROL
WORKING�TEMP.
RC+/RC-:�Short�=�power�on�;�Open�=�power�off
-10�~�+50 (Refer�to�output�load�derating�curve)
20�~�90%�RH non-condensing
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
STORAGE�TEMP.,�HUMIDITY
ENVIRONMENT
TEMP.�COEFFICIENT
VIBRATION
0.03%/ (0�~�50
)
10�~�500Hz,�2G�10min./1cycle,�period�for 60min.�each�along�X, Y,�Z�axes
UL60950-1, TUV�EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
SAFETY &
Compliance�to�EN55022�(CISPR22)�Class�B
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMC
(Note�4)
Compliance�to EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204, Light�industry�level,��criteria A
EMS�IMMUNITY
MTBF
133.4K�hrs�min.������MIL-HDBK-217F�(25
170*120*93mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.9Kg;�8pcs/15.5Kg/1.06CUFT
�ꢀꢁꢂꢃꢃꢁꢄꢅꢆꢅꢇꢈꢉꢈꢆꢊꢁꢋꢌꢍꢁꢊꢄꢈꢎꢏꢅꢃꢃꢐꢁꢇꢈꢑꢉꢏꢒꢑꢈꢓꢁꢅꢆꢈꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢅꢉꢁꢕꢖꢗꢘꢂꢙꢁꢏꢑꢄꢔꢉꢚꢁꢆꢅꢉꢈꢓꢁꢃꢒꢅꢓꢁꢅꢑꢓꢁꢕꢛ ꢒꢜꢁꢅꢇꢝꢏꢈꢑꢉꢁꢉꢈꢇꢄꢈꢆꢅꢉꢔꢆꢈꢀ
ꢕꢀꢁꢞꢏꢄꢄꢃꢈꢁꢟꢁꢑꢒꢏꢊꢈꢁꢅꢆꢈꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢅꢉꢁꢕꢗꢠꢡꢢꢁꢒꢜꢁꢝꢅꢑꢓꢣꢏꢓꢉꢤꢁꢝꢐꢁꢔꢊꢏꢑꢥꢁꢅꢁ�ꢕꢦꢁꢉꢣꢏꢊꢉꢈꢓꢁꢄꢅꢏꢆꢧꢣꢏꢆꢈꢁꢉꢈꢆꢇꢏꢑꢅꢉꢈꢓꢁꢣꢏꢉꢤꢁꢅꢁꢗꢀ�ꢔꢜꢁꢟꢁꢨꢩꢔꢜꢁꢄꢅꢆꢅꢃꢃꢈꢃꢁꢎꢅꢄꢅꢎꢏꢉꢒꢆꢀ
ꢖꢀꢁꢍꢒꢃꢈꢆꢅꢑꢎꢈꢁꢪꢁꢏꢑꢎꢃꢔꢓꢈꢊꢁꢊꢈꢉꢁꢔꢄꢁꢉꢒꢃꢈꢆꢅꢑꢎꢈꢚꢁꢃꢏꢑꢈꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢁꢅꢑꢓꢁꢃꢒꢅꢓꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢀ
ꢨꢀꢁꢍꢤꢈꢁꢄꢒꢣꢈꢆꢁꢊꢔꢄꢄꢃꢐꢁꢏꢊꢁꢎꢒꢑꢊꢏꢓꢈꢆꢈꢓꢁꢅꢁꢎꢒꢇꢄꢒꢑꢈꢑꢉꢁꢣꢤꢏꢎꢤꢁꢣꢏꢃꢃꢁꢝꢈꢁꢏꢑꢊꢉꢅꢃꢃꢈꢓꢁꢏꢑꢉꢒꢁꢅꢁꢜꢏꢑꢅꢃꢁꢈꢫꢔꢏꢄꢇꢈꢑꢉꢀꢁꢍꢤꢈꢁꢜꢏꢑꢅꢃꢁꢈꢫꢔꢏꢄꢇꢈꢑꢉꢁꢇꢔꢊꢉ ꢝꢈꢁꢆꢈꢧꢎꢒꢑꢜꢏꢆꢇꢈꢓꢁꢉꢤꢅꢉꢁꢏꢉꢁꢊꢉꢏꢃꢃꢁꢇꢈꢈꢉꢊ
ꢬꢠꢙꢁꢓꢏꢆꢈꢎꢉꢏꢭꢈꢊꢀ
ꢛꢀꢁꢮꢈꢆꢅꢉꢏꢑꢥꢁꢇꢅꢐꢁꢝꢈꢁꢑꢈꢈꢓꢈꢓꢁꢔꢑꢓꢈꢆꢁꢃꢒꢣꢁꢏꢑꢄꢔꢉꢁꢭꢒꢃꢉꢅꢥꢈꢊꢀꢁꢯꢃꢈꢅꢊꢈꢁꢎꢤꢈꢎꢰꢁꢉꢤꢈꢁꢓꢈꢆꢅꢉꢏꢑꢥꢁꢎꢔꢆꢭꢈꢁꢜꢒꢆꢁꢇꢒꢆꢈꢁꢓꢈꢉꢅꢏꢃꢊꢀ
300 Myleꢀ standiꢀh Blvd., Taunton, MA 02780
WWW.AsTRODYNE.COM
ph: 1-800-823-8082
Fax: 508-823-8181