RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
RSG
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
ELECTRONIC COMPONENTS
Änderungen vorbehalten / subject to change without notice
500W Single Output with PFC Function
SP-500 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Built-in remote sense function
Fixed switching frequency at 110KHz
3 years warranty
SPECIFICATION
MODEL
SP-500-12
SP-500-13.5
SP-500-15
SP-500-24
SP-500-27
SP-500-48
DC VOLTAGE
12V
13.5V
36A
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
40A
32A
20A
18A
10A
0 ~ 40A
480W
0 ~ 36A
486W
0 ~ 32A
480W
0 ~ 20A
480W
0 ~ 18A
486W
200mVp-p
24 ~ 30V
1.0%
0 ~ 10A
480W
300mVp-p
41 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 240mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
240mVp-p
12 ~ 15V
1.0%
240mVp-p
13.5 ~ 18V
1.0%
240mVp-p
20 ~ 26.4V
1.0%
OUTPUT
10 ~ 13.2V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1500ms, 50ms at full load
24ms at full load
VOLTAGE RANGE
Note.5 88 ~ 264VAC
124 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY(Typ.)
47 ~ 63Hz
PF>0.95/230VAC
84%
PF>0.95/115VAC at full load
INPUT
84%
83%
85.5%
86.5%
87%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
7A/115VAC
18A/115VAC
<3.5mA/240VAC
3.5A/230VAC
36A/230VAC
105 ~ 135% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V
OVER LOAD
57.6 ~ 67.2V
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH1 or RTH2 50 FAN ON, 45 FAN OFF, 70 output shutdown
FAN CONTROL, O.T.P.
FUNCTION REMOTE CONTROL
WORKING TEMP.
RC+/RC-: Short = power on ; Open = power off
-10 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
Compliance to EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMC
(Note 4)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
EMS IMMUNITY
MTBF
133.4K hrs min. MIL-HDBK-217F (25
170*120*93mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.9Kg; 8pcs/15.5Kg/1.06CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-500-SPEC 2005-09-13