Power Supplies
3
Silver Line Series – Single & Multi-Output Linears
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Standard
screw terminal connections and optional covers are offered
for safety considerations.
Applications
• Industrial Control Circuits and Components
• Instrumentation
E137632
• Drives
Specifications
• CNC Machinery
Parameter
Condition
Input
Limit
• Equipment for food industry
• Microprocessor Circuits
• Analog Circuits
100/120/220/230/240
Vac Selectable
Input Voltage
47-63 Hz
Input Frequency
• Noise sensitive Circuitry and Sensors
Output
for 10% change
0.05%
0.05%
Line Regulation
Load Regulation
Features
for 50% change
3.0 mV maximum
Peak-to-Peak
• Easy-to-install screw terminal connections
• Cover options
Ripple
DC Output
Adjustment Range
±5% Minimum
• Industry standard footprint
• Universal input and approvals (115/230 Vac)
All 5-Volt outputs include
build-in OVP as standard
(setting is 6.2 V ±0.4 V)
OVP is optionally
Overvoltage
Protection
• Low noise, extremely quiet DC output. For noise
sensitive or analog circuitry.
available on other types
Transient
Response Time
• Fast transient response. Ideal for test applications.
at 50% Load Changes
50 msec.
• Built-in OVP on 5 V models and optional on
Automatic current
limit foldback
Overload
Protection
12, 15 and 24 V models
Available to compensate
for output voltage drop
on selected models.
• Automatic resetting overload protection
• Short circuit protected
0.5 Vdc
Remote Sensing
General
• Two year limited warranty
Operating
Temperature Range
Derate to 40% at +70°C
0 to +50°C
Certifications and Compliances
Storage
Temperature Range
-25°C to +85°C
•
Recognized Component, ITE
- UL 60950-1
Certified, ITE
Temperature
Coefficient (Typical)
0.01% 0°C
±.5%
•
After warm-up
Stability
- CSA C22.2 CSA 60950-1
For most system
Linear power supplies
have inherently low
conducted and radiate
noise levels
applications they will
meet requirements of
FCC Class B and VDE
0871 for Class B
•
EMI/RFI
- IEC60950-1
Derate power by an additional 15%
Cover Option
Cooling
Forced air. 20 CFM required for full rating
Derate 30% without cooling
Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical.
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.