SKS B1 090 GD 69/11 - MA PB
T
AMBIENT=40°C unless otherwise specified
Environmental conditions
Characteristics
Climatic
Conditions
min
typ
max
Unit
Ambient temperature 3
)
Storage: IEC 60721-3-1, class 1K2
Transportation: IEC 60721-3-2, class 2K2
-25
-20
5
60
55
85
°C
°C
%
Operation: IEC 60721-3-3, class 3K3 extended
Humidity
IEC 60721-3-3, class 3K3
no condensation no icing
Mechanical
Installation altitude
without derating
1 000
4 000
m
m
-
Max installation altitude
Ingress protection
with derating
IEC 60529
IP00
2M1
3M3
2
IEC 60721-3-2, Storage & transportation
IEC 60721-3-3, in operation
EN 50178
-
Vibrations & Shocks
Pollution degree
Mass
-
-
SKiiP stack
3-phase inverter, with cable plate terminal and no
DC bus connection
85
kg
Thermal data
∆V/∆tWATER
Water flow of the 3-phase inverter
8
16
310
3
35
L/min
mbar
SEMISTACK® Renewable Energy - Size W1
Water pressure drop of the inverter, with male and
female connectors, 50% glycol, 16 L/min
Two Quadrant 3-phase IGBT inverter
∆PWATER
Water pressure
Rated water pressure per inverter
Recommended coolant
bar
-
50% glycol / 50% water
Coolant type
TINLET
Cooling water inlet temperature
Airflow direction bottom to top on snubbers 3)
-20
45
1
60
°C
m.s-1
Ordering No. 08800136
Required cooling airflow
Description SKS B1 090 GD 69/11 - MA PB
VSUPPLY
PFAN
VDC
Fan DC voltage supply
16
24
90
57
30
Features
Fan power consumption at typical voltage supply
Capacitor DC fan lifetime expectancy (L10 method)
W
LTE
kh
ó Designed in regard to EN50178
and UL508C recommendations
ó Designed for a 600 x 600 x 2000 mm cabinet
ó Embedded SKiiP® Technology 3
ó SKiiP 1513GB172-3DW, Trench 3 1700V IGBT,
CAL3 diode
T
AMBIENT=25°C unless otherwise specified
Gate Driver Characteristics
Symbol
Conditions
min
typ
max
Unit
Gate Driver / controler data
VS
supply voltage non stabilized
13
24
30
V
mA
V
2
IS
VS2 = 24 V, FSW in kHz, IRMS in A
input threshold voltage HIGH
input threshold voltage LOW
Input resistance
300 + 42×Fsw + 0.00044×IRMS
ViT+
ViT-
RIN
CIN
12.3
4.6
10
ó Integrated current and temperature sensors
ó Water cooling
V
kΩ
nF
Typical Applications
ó Wind generators (SG and DFIG)
ó Solar Inverters
Input capacitance
1
Measurement & protection
A.V-1
HB_I
Analogue current signal HB_I
184
188
191
1 912
ITRIP SC
(Ianalogue OUT=10V)
APEAK
Over current trip level
1 837
1 875
Footnotes
°C
°C
°C
°C
°C
°C
°C
min 17 + 10.3×CMN_TMP
Analogue temperature signal Th < 80°C
CMN_TMP
typ
19 + 10.5×CMN_TMP
20 + 10.5×CMN_TMP
3) the user shall ensure that the ambient air is sufficiently
ventilated to avoid hot spots.
max
min 26 + 8.8×CMN_TMP
Analogue temperature signal Th > 80°C
Over temperature protection
CMN_TMP
TTRIP
typ
28 + 8.8×CMN_TMP
30 + 8.9×CMN_TMP
115 120
max
110
REMARKS
This technical information specifies semiconductor devices but
promises no characteristics. No warranty or guarantee,
expressed or implied is made regarding delivery, performance
or suitability.
B6CI
Rev. 2 - 15.04.2013
© by SEMIKRON
2