5秒后页面跳转
SKS B2 120 GD 69/11 - MA PB PDF预览

SKS B2 120 GD 69/11 - MA PB

更新时间: 2024-11-06 14:53:31
品牌 Logo 应用领域
赛米控丹佛斯 - SEMIKRON /
页数 文件大小 规格书
6页 531K
描述
Stacks Frame W2

SKS B2 120 GD 69/11 - MA PB 数据手册

 浏览型号SKS B2 120 GD 69/11 - MA PB的Datasheet PDF文件第2页浏览型号SKS B2 120 GD 69/11 - MA PB的Datasheet PDF文件第3页浏览型号SKS B2 120 GD 69/11 - MA PB的Datasheet PDF文件第4页浏览型号SKS B2 120 GD 69/11 - MA PB的Datasheet PDF文件第5页浏览型号SKS B2 120 GD 69/11 - MA PB的Datasheet PDF文件第6页 
SKS B2 120 GD 69/11 - MA PB  
Absolute maximum ratings 1)  
Symbol  
IOUT MAX  
IIN MAX  
Conditions  
Values  
1 200  
1 800  
760  
Unit  
ARMS  
ADC  
Maximum permanent output current  
Maximum permanent input current  
Maximum output voltage  
Maximum DC Bus voltage  
Inverter output frequency  
Maximum switching frequency  
VAC  
VOUT MAX  
VBUS MAX  
FOUT MAX  
FSW MAX  
VDC  
1 200  
100  
Hz  
5
kHz  
Electrical characteristics: application example  
TAMBIENT=40°C unless otherwise specified  
Symbol  
AC phase  
VBUS  
Conditions  
min  
typ  
max  
Unit  
VDC  
ARMS  
ARMS  
DC bus rated voltage  
Rated output current  
Overload output current  
Overload duration  
1 100  
1 200  
1 320  
60  
IOUT RATED  
IOUT OVL  
tOVL  
s
min  
VAC  
kW  
kHz  
Hz  
-
TINLET=45°C, 50% glycol,  
Flowrate = 16 L/min  
TJ<125°C,  
SKiiP stack  
TOVL  
Time between 2 overloads  
Output voltage  
10  
VOUT  
620  
690  
1 430  
2
760  
POUT  
ambient air temperature = 40°C,  
air extraction according to  
thermal data page 2  
Rated output power  
Inverter switching frequency  
Output frequency  
FSW  
SEMISTACK® Renewable Energy - Size W2  
FOUT  
50  
Two Quadrant 3-phase IGBT inverter  
PF  
Power factor  
1
2)  
Losses at rated current  
Efficiency at rated current  
13 840  
>99  
W
PLOSS INV  
2)  
η
%
Ordering No. 08800415  
DC Bus  
VBUS  
Description SKS B2 120 GD 69/11 - MA PB  
VDC  
VDC  
min  
mF  
kh  
Rated DC voltage applied to the capacitor bank  
Max DC voltage applied to the caps bank (max 30% of LTE)  
Discharge time of the capacitors (VDC < 60 V)  
Capacitor bank capacity  
1 100  
VBUS MAX  
τd5%  
Features  
1 200  
7
CDC  
10,0  
100  
ó Designed in regard to EN50178  
and UL508C recommendations  
ó Designed for a 600 x 600 x 2000 mm cabinet  
ó Embedded SKiiP® Technology 3  
ó SKiiP 2403GB172-4DW, Trench 3 1700V IGBT,  
CAL3 diode  
LTE  
Calculated LTE of the caps with forced air cooling  
Stack Insulation  
Crd  
Minimum creepage distance  
11  
9.4  
mm  
mm  
Cld  
Minimum clearance distance  
VDC  
Visol  
dv/dt  
Chassis / power stage AC/DC (insulation test voltage DC, 5s)  
SKiiP driver only, secondary to primary side  
-4 200  
4 200  
ó Integrated current and temperature sensors  
ó Water cooling  
75  
kV/µs  
Typical Applications  
ó Wind generators (SG and DFIG)  
ó Solar Inverters  
Footnotes  
1) Absolute maximum ratings are values not to be  
exceeded in any case and do not imply that the stack  
can operate in all these conditions taken together.  
2) fan consumption and losses in air included  
REMARKS  
This technical information specifies semiconductor devices but  
promises no characteristics. No warranty or guarantee,  
expressed or implied is made regarding delivery, performance  
or suitability.  
B6CI  
Rev.02 - 16.04.2013  
© by SEMIKRON  
1