SKS SL 20 GD 50/10 - E4 P1
Absolute maximum ratings
Values
230
Symbol
IOUT MAX
IIN MAX
Conditions
Unit
ARMS
ADC
Maximum permanent output current
Maximum permanent input current
Maximum output voltage
250
VAC
VOUT MAX
VBUS MAX
530
VDC
1 100
500
Maximum DC bus voltage (without switching)
Maximum inverter output frequency
Maximum switching frequency
f
OUT
Hz
15
fSW
kHz
Electrical characteristics / Typical PV solar application
T cooling air 1) = 40°C unless otherwise specified
Symbol
Ratings
IOUT RATED
VOUT
Conditions
min
typ
max
Unit
ARMS
VAC
Rated output current
Rated output voltage
Power factor
200
360
1
No overload,
Chip junction T° < 150°C,
(Max junction temperature = 175°C)
PF
-
IGBT Module stack
POUT
Rated output power
Inverter switching frequency
Output frequency
125
3
kW
kHz
Hz
fSW
with SEMIKRON axial fan
fOUT
"AF" option 2)
or
50
VDC
VBUS
Rated DC voltage
Total power losses
Inverter lifetime
800
1 770
100 1)
SEMIKUBE® SlimLine - Frame SL20
3-phase IGBT inverter
PLOSS INV
LΤΕ
580m3/h min
W
kHrs
Ordering No. 08801374
Description SKS SL 20 GD 50/10 - E4 P1 AF
Ordering No. 08801373
Electrical characteristics / Typical AC-Drive application
T cooling air 1) = 40°C unless otherwise specified
Symbol
Ratings
IOUT RATED
VOUT
Conditions
min
typ
max
Unit
Description SKS SL 20 GD 50/10 - E4 P1 G
ARMS
VAC
Rated output current
Rated output voltage
Power factor
162
400
0,85
100
3
Overload 150% / 1min / 5min
Chip junction T° < 150°C,
with SEMIKRON axial fan
PF
-
Features
ó Slim design for 300mm deep cabinet
ó IP54 heatsink side
POUT
Rated output power
Inverter switching frequency
Output frequency
kW
kHz
Hz
fSW
"AF" option 2)
or
fOUT
ó Fast mounting and dismounting
100
650
1 444
100 1)
VDC
ó Current measurement accuracy <2% of IOUT RATED at 25°C
ó Overvoltage, short circuit, and overtemperature protection
ó Air cooled power stack
VBUS
Rated DC voltage
Total power losses
Inverter lifetime
580m3/h min
PLOSS INV
LΤΕ
W
kHrs
ó UL 1741, UL 508 C and IEC 62109-1 Ready
ó HE10 driver interface (34 pts)
Filtering characteristics
VBUS
VDC
VDC
s
ó CAN interface for error storage, diagnostic and setting
Rated DC voltage applied to the caps bank with switching
Max DC voltage applied to the caps bank without switching
Discharge time of the capacitors (5%)
800
300
100
1 000
1 100
VDC CAP
τd5%
CDC
LTE
Capacitor bank capacity
0,71
0,79
mF
kHrs
Typical Applications
Calculated LTE of the caps with forced air cooling
ó Solar PV Inverter
ó Sectionnal AC Drive
ó Active Front End
Stack Insulation
VISOL
Frame / Power stage AC/DC (insulation test voltage DC, 60s)
4 200
V
Remarks
For information regarding installation and conditions of use,
please refer to SEMIKUBE SlimLine user manual
Footnotes
1) Tcooling air =40°C, < 1000m, with fan option (AF type)
Tcabinet = 55°C with 2m/s air ventilation inside cabinet on
stack to avoid hot spots
2) Performances with "AF" option on AC side according
drawing page 4&7
S K S S L
2 0 G D 5 0 / 9 0 E 4 P 1 A F
SEMIKRON Solution Center Stack
Platform name
SL
Maximum AC Output Current of the converter
20 : 200 ARMS
Stack topology
: SEMIKUBE SlimLine
GD
: 3-phase IGBT inverter
Voltages
AC
DC
50/90 : Rated 500V Output voltage / 900V Bus Voltage
IGBT semiconductor technology
E4
: SEMITRANS E4
Power capacitor technology
P1
: polypropylene 1,100V type #1
Cooling type
G
AF
: forced air convection, supplied by the customer
: forced air convection, power assembly delivered with axial fans
B6CI
Rev. 3.0 - 23.08.2019
© by SEMIKRON
1