5秒后页面跳转
SKS B2 140 GDD 69/12 U - A11 MA PB PDF预览

SKS B2 140 GDD 69/12 U - A11 MA PB

更新时间: 2024-11-06 14:55:39
品牌 Logo 应用领域
赛米控丹佛斯 - SEMIKRON /
页数 文件大小 规格书
6页 588K
描述
Stacks Frame W2

SKS B2 140 GDD 69/12 U - A11 MA PB 数据手册

 浏览型号SKS B2 140 GDD 69/12 U - A11 MA PB的Datasheet PDF文件第2页浏览型号SKS B2 140 GDD 69/12 U - A11 MA PB的Datasheet PDF文件第3页浏览型号SKS B2 140 GDD 69/12 U - A11 MA PB的Datasheet PDF文件第4页浏览型号SKS B2 140 GDD 69/12 U - A11 MA PB的Datasheet PDF文件第5页浏览型号SKS B2 140 GDD 69/12 U - A11 MA PB的Datasheet PDF文件第6页 
SKS B2 140 GDD 69/12 U – A11 MA PB  
Absolute maximum ratings 1)  
Symbol  
Conditions  
Values  
1 400  
760  
Unit  
ARMS  
VAC  
VDC  
Hz  
IIN/OUT MAX  
VIN/OUT MAX  
VBUS MAX  
Maximum permanent input/output current  
Maximum permanent input/output voltage  
Maximum DC Bus voltage  
1 300  
100  
FIN/OUT MAX  
FSW IN/OUT MAX  
Maximum rectifier/inverter output frequency  
Maximum switching frequency  
5
kHz  
TAMBIENT=40°C unless otherwise specified  
Electrical characteristics  
Symbol Conditions  
AC phase Grid  
min  
typ  
max  
Unit  
IOUT RATED  
IOUT OVL  
tOVL  
ARMS  
ARMS  
s
Rated output current  
Overload output current  
Overload duration  
1 400  
1 540  
60  
VBUS=1250 VDC  
,
TOVL  
Time between 2 overloads  
Output voltage  
10  
min  
VAC  
kW  
kHz  
Hz  
-
TINLET = 45°C, 50% glycol  
Flowrate = 16 L/min  
TJ <150°C  
VOUT  
620  
690  
1 670  
2
760  
SKiiP stack  
POUT  
Rated output power  
Inverter switching frequency  
Output frequency  
Ambient temperature = 40°C  
air extraction according to thermal  
data page 2  
FSW OUT  
FOUT  
50  
SEMISTACK® Renewable Energy - Size W2  
PF  
Power factor  
1
2)  
Losses at rated current  
Efficiency at rated current  
18 200  
99  
W
PLOSS INV  
2)  
4-Quadrant 3-phase IGBT converter  
%
η
AC phase Generator  
ARMS  
ARMS  
IIN RATED  
IIN OVL  
tOVL  
Ordering No. 08800588  
Rated input current  
Overload input current  
Overload duration  
1 400  
1 540  
60  
Description SKS B2 140 GDD 69/12 U – A11 MA PB  
s
VBUS = 1250 VDC  
TOVL  
VIN  
Time between 2 overloads  
Input voltage  
10  
Features  
min  
VAC  
TINLET = 45°C, 50% glycol  
Flowrate = 16 L/min  
TJ<150°C  
620  
690  
1 670  
2
760  
PIN  
Rated input power  
kW  
kHz  
Hz  
-
ó Designed in regard to EN50178 recommendations  
and UL508C recommendations  
ambient temperature = 40°C  
air extraction according to thermal  
data page 2  
FSW IN  
FIN  
Rectifier switching frequency  
Input frequency  
50  
ó Designed for a 600 x 600 x 2000 mm cabinet  
ó Embedded SKiiP® Technology 4  
ó SKiiP 2414GB17E4-4DUW, Trench 4 1700V IGBT,  
CAL4 diode  
PF  
Power factor  
-1  
2)  
Losses at rated current  
Efficiency at rated current  
17 600  
99  
W
PLOSS REC  
2)  
η
%
ó Integrated current, temperature & voltage sensors  
ó Water cooling  
DC Bus  
VBUS  
VDC  
VDC  
min  
mF  
kh  
Rated DC voltage applied to the capacitor bank  
Max DC voltage applied to the caps bank (max 30% of LTE)  
Discharge time of the capacitors (VDC < 60 V)  
Capacitor bank capacitance  
1 250  
VBUS MAX  
τd5%  
1 300  
100  
Typical Applications  
ó Wind generators (SG and DFIG)  
ó Solar inverters  
6
C
DC  
16,2  
LTE  
Calculated LTE of the caps with forced air cooling  
Footnotes  
1) Absolute maximum ratings are values not to be  
exceeded in any case and do not imply that the stack  
can operate in all these conditions taken together.  
Stack Insulation  
Crd  
Minimum creepage distance  
11  
9.4  
mm  
mm  
Cld  
Minimum clearance distance  
VDC  
Visol  
dv/dt  
Chassis / Power stage AC/DC (insulation test voltage DC, 5s)  
SKiiP driver only, secondary to primary side  
-4 200  
4 200  
75  
2) fan consumption and losses in air included  
kV/µs  
REMARKS  
This technical information specifies semiconductor devices but  
promises no characteristics. No warranty or guarantee,  
expressed or implied is made regarding delivery, performance  
or suitability.  
B6CI + B6CI  
Rev. 2 - 16.04.2013  
© by SEMIKRON  
1