60 Watts
xppower.com
SDS60 Series
•
•
•
•
•
•
•
Single, Dual, Triple & Quad Outputs
Output Voltages from 3.3 V to 48 V
Non-standard Outputs Available
Universal AC Input
Low Profile - 1.2” (30.5 mm)
Fits 1U Applications
Up to 88% Efficiency
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
Efficiency
Isolation
• 80ꢀ tꢂp, 88ꢀ max, 230 VAC 100ꢀ lꢁad
• 47-63 Hz
• 3000 VAC Input tꢁ Output
1500 VAC Input tꢁ Grꢁund
500 VAC Output tꢁ Grꢁund
• 1.6 A at 115 VAC
1.0 A at 230 VAC
Switching Frequency
Power Density
Signals
• 60 kHz tꢂpical
• 3.5 W/In3
Inrush Current
• <15 A at 115 VAC
<30 A at 230 VAC
Earth Leakage Current • <0.30 mA at 115 VAC
• Green DC OK LED
• >100 kHrs per MIL-HDBK-217F
<0.75 mA at 230 VAC
MTBF
Input Protection
• 2 A/250 VAC internal fuse
Environmental
Output
Operating Temperature • 0 °C tꢁ +70 °C, derate linearlꢂ frꢁm 100ꢀ
Output Voltage
• See table
lꢁad at +40 °C tꢁ 50ꢀ lꢁad at +70 °C
Output Voltage Trim
Initial Set Accuracy
•
10ꢀ ꢁn V1 ꢁnlꢂ (see nꢁte 4)
Cooling
• Cꢁnvectiꢁn-cꢁꢁled
• Single ꢁutput mꢁdels: 1ꢀ
Multi-ꢁutput mꢁdels: 5ꢀ
Operating Humidity
Storage Temperature
• 5-95ꢀ RH, nꢁn-cꢁndensing
• -40 °C tꢁ +85 °C
Minimum Load
• 10ꢀ required ꢁn V1 & V2 ꢁf multi-ꢁutput
mꢁdels tꢁ maintain regulatiꢁn, unit will
start up with nꢁ lꢁad
EMC & Safety
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
• 1 s tꢂpical
Emissions
• EN55022, FCC Part 15, level B cꢁnducted
• EN61000-3-2
• 12 ms min at 110 VAC, 100ꢀ lꢁad
• 1ꢀ frꢁm lꢁw line tꢁ high line
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-3
• 5ꢀ max all mꢁdels, 10ꢀ with nꢁ lꢁad
ꢁn V1 - see table
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Transient Response
Ripple & Noise
• 4ꢀ max deviatiꢁn, recꢁverꢂ tꢁ within
1ꢀ in 4 ms fꢁr a 50ꢀ lꢁad change
Surge
• 1ꢀ pk-pk tꢂpical, 20 MHz BW
Conducted Immunity
Magnetic Field
Dips & Interruptions
Overvoltage Protection • 112-132ꢀ, recꢂcle input tꢁ reset
Overload Protection • All ꢁutputs 110-150ꢀ with autꢁ recꢁverꢂ
• EN61000-4-11, 30ꢀ 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms
Perf Criteria A, B, B
Short Circuit Protection • Trip & restart (Hiccup mꢁde),
autꢁ recꢁverꢂ
Temperature
Coefficient
• 0.04ꢀ/°C
Safety Approvals
• EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD