60 Watts
xppower.com
SDS Series
•
•
•
•
•
•
•
Single, Dual, Triple & Quad Outputs
Output Voltages from 3.3 V to 48 V
Nonꢀstandard Outputs Available
Industry Standard 3” x 5” Package
Fits 1U Applications
Open Frame, U Channel & Covered Versions
3 Year Warranty
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 1.6 A max at 115 VAC
1.0 A max at 230 VAC
Efficiency
Isolation
• 80ꢀ typical, 230 VAC full load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
Switching Frequency
Power Density
Signals
• 60 kHz typical
• 3.5 W/In
• Green DC OK LED
Inrush Current
• <15 A at 115 VAC, cold start at 25 °C
<30 A at 230 VAC, cold start at 25 °C
3
Earth Leakage Current • <0.30 mA at 115 VAC
<0.75 mA at 240 VAC
• EN61000-3-2, Class A
MTBF
• 190 kHrs typical to MIL-HDBK-217F
at 25 °C, GB
Power Factor
Input Protection
• T2 A/250 VAC internal fuse in line
Environmental
Output
Operating Temperature • 0 °C to +70 °C, derate linearly from 100ꢀ
load at +50 °C to 50ꢀ load at +70 °C
Output Voltage
• See table
Cooling
• Convection-cooled
• 5-95ꢀ RH, non-condensing
Output Voltage Trim
Initial Set Accuracy
•
10ꢀ on V1 only (see note 4)
Operating Humidity
• Single output models: 1ꢀ
Multi-output models: 5ꢀ
Storage Temperature • -40 °C to +85 °C
Minimum Load
• 10ꢀ required on V1 & V2 of multi-output
models to maintain regulation, unit will
start up with no load
EMC & Safety
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
• 2 s typical
• 12 ms min at 110 VAC, 100ꢀ load
• 1ꢀ from low line to high line
• 7ꢀ max all models 3ꢀ typical, see table
10ꢀ with no load on V1, for multi output
models
• 4ꢀ max deviation, recovery to within
1ꢀ in 4 ms for a 50ꢀ load change
Emissions
• EN55022, level B conducted and radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 2 contact, level 3 air,
Perf Criteria A
• EN61000-4-3, level 2, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Transient Response
Ripple & Noise
Surge
• EN61000-4-5, installation Class 3,
Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
• EN61000-4-11, 30ꢀ 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms
Perf Criteria A, B, B
• 1ꢀ pk-pk typical, 20 MHz bandwidth
Overvoltage Protection • 112-132ꢀ of nominal output voltage on
Conducted Immunity
Magnetic Field
V1 only, recycle input to reset
Overload Protection
• 110-150ꢀ of nominal power,
with auto recovery
Dips & Interruptions
Short Circuit Protection • Trip & restart (hiccup mode),
auto recovery
Safety Approvals
• EN60950-1, UL60950-1,
CSA60950-1 per cUL
Temperature
Coefficient
•
0.04ꢀ/°C