50W Single Output DC-DC Converter
SD-50 series
Features :
2:1 wide input range
Protections:Short circuit/Over load/Over voltage
1500VDC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
Low cost
High reliability
1 year warranty
SPECIFICATION
MODEL
SD-50A-5
SD-50B-5
SD-50C-5
SD-50A-12 SD-50B-12 SD-50C-12 SD-50A-24 SD-50B-24 SD-50C-24
DC VOLTAGE
5V
12V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
10A
4.2A
2.1A
0 ~ 10A
50W
0 ~ 4.2A
50.4W
120mVp-p
11 ~ 16VDC
1.0%
0 ~ 2.1A
50.4W
150mVp-p
23 ~ 30VDC
1.0%
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC
VOLTAGE TOLERANCE Note.3 2.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT
0.5%
0.5%
0.3%
0.2%
0.3%
0.2%
2.5s, 50ms, ------ at full load
A:9.2 ~ 18VDC
70%
B:19 ~ 36VDC
C:36 ~ 72VDC
72%
73%
76%
75%
78%
74%
80%
83%
INPUT
7A/12V
3A/24V
1.5A/48V
105 ~ 150% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V/10% load 16.8 ~ 20V/10% load 31.5 ~ 37.5V/10% load
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to LVD
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,6,8; ENV50204, EN55024,heavy industry level, criteria A
365.6K hrs min.(SD-50A)
159*97*38mm (L*W*H)
357.5K hrs min.(SD-50B)
368.5K Hrs min.(SD-50C) MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
0.53Kg; 24pcs/12.7Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SD-50-SPEC 2003-12-26