SCp-2k4 series
ꢘꢒꢦꢆꢅꢑꢒꢞꢁꢟ
�ꢀꢁꢂꢃꢄꢅꢆꢁꢇꢈꢉꢊꢋꢌꢉꢍ�ꢀꢎꢁꢏ ꢏꢁꢐꢂꢑꢒ
2400W Parallel Type With PFC Function
�ꢀꢁꢋꢋꢉꢍꢎꢁꢇ ꢓꢑꢁꢏꢈꢉꢍꢎꢁꢏ ꢔꢁꢐꢂꢑꢒꢕꢓꢄꢆꢂꢓꢃꢖ
ꢗꢘꢙꢁꢉꢚꢛꢈꢜꢁꢋꢏꢉꢍ�ꢀ
ꢗꢑꢓꢆꢒꢝꢆꢂꢓꢃꢞꢟꢁꢠꢡꢓꢑꢆꢁꢝꢂꢑꢝꢅꢂꢆꢢꢁꢣꢤꢒꢑꢥꢓꢦꢧꢢꢁꢣꢤꢒꢑꢁꢤꢓꢥꢆꢦꢨꢒꢢꢁꢣꢤꢒꢑꢁꢆꢒꢩꢄꢒꢑꢦꢆꢅꢑꢒ
ꢪꢅꢂꢥꢆꢫꢂꢃꢁꢑꢒꢩꢓꢆꢒꢁꢞꢒꢃꢞꢒꢁꢬꢅꢃꢝꢆꢂꢓꢃꢎꢁꢑꢒꢩꢓꢆꢒꢁꢣꢭꢫꢣꢘꢘꢁꢝꢓꢃꢆꢑꢓꢥ
ꢗꢓꢐꢒꢑꢁꢨꢓꢓꢧꢁꢞꢂꢨꢃꢦꢥ
ꢮꢂꢆꢡꢁꢄꢦꢑꢦꢥꢥꢒꢥꢁꢬꢅꢃꢝꢆꢂꢓꢃꢕꢭꢯꢇꢖ
ꢀꢦꢃꢁꢦꢧꢰꢅꢞꢆꢁꢬꢑꢓꢩꢁꢋꢉꢊꢇꢉꢉꢱꢁꢓꢅꢆꢄꢅꢆꢁꢤꢓꢥꢆꢦꢨꢒꢁꢲꢳꢁꢒꢴꢆꢒꢑꢃꢦꢥꢁꢝꢓꢃꢆꢑꢓꢥꢁꢇꢫꢵꢍ
ꢘꢓꢑꢝꢒꢧꢁꢦꢂꢑꢁꢝꢓꢓꢥꢂꢃꢨꢁꢲꢳꢁꢲꢅꢂꢥꢆꢫꢂꢃꢁꢶꢀꢁꢬꢦꢃ
ꢀꢦꢞꢒꢁꢝꢓꢦꢆꢂꢃꢨꢁꢐꢂꢆꢡꢁꢄꢦꢂꢃꢆ
ꢏꢁꢳꢒꢦꢑꢞꢁꢐꢦꢑꢑꢦꢃꢆꢳ
SPECIFICATION
ORDER�NO.
SCP-2K4-09 SCP-2K4-12 SCP-2K4-15 SCP-2K4-18 SCP-2K4-24 SCP-2K4-36 SCP-2K4-48 SCP-2K4-60
SAFETY MODEL NO.
DC�VOLTAGE
2K4S-P009
9V
2K4S-P012
12V
2K4S-P015
15V
2K4S-P018
18V
2K4S-P024
24V
2K4S-P036
36V
2K4S-P048
48V
2K4S-P060
60V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
266A
200A
160A
133A
100A
66A
50A
40A
0�~�266A
2400W
0�~�200A
2400W
0�~�160A
2400W
0�~�133A
2400W
0�~�100A
2400W
0�~�66A
2400W
200mVp-p
0�~�50A
2400W
200mVp-p
0�~�40A
2400W
200mVp-p
OUTPUT
RIPPLE�&�NOISE�(max.) Note.2 90mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 2.0%
120mVp-p
150mVp-p
150mVp-p
150mVp-p
5.0% Typical�adjustment�by�potentiometer����������20%~100%�adjustment�by�1~5VDC�external�control
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE�REGULATION
0.5%
1.5%
LOAD�REGULATION
SETUP,�RISE,�HOLD�TIME
800ms,�400ms,�12ms�at�full�load
VOLTAGE�RANGE
FREQUENCY RANGE
POWER�FACTOR
180�~�260VAC�����������3 3�wire�(other�system�available)
47~63Hz
>0.98�/�230VAC
INPUT
EFFICIENCY (Typ.)
AC�CURRENT
83%
84%
85%
86%
88%
88%
89%
89%
15A /�230VAC
60A /�230VAC
3.5mA /�240VAC
INRUSH�CURRENT�(max.)
LEAKAGE�CURRENT(max.)
110~140%�rated�output�power
OVER�LOAD
Note.�4
Protection�type�:�Current�limiting,�delay�shut�down�o/p�voltage,�re-power�on�to�recover
110�~�135% Follow�to�output�set�up�point
PROTECTION OVER�VOLTAGE
Protection�type�:�Shut�down�o/p�voltage,�re-power�on�to�recover
>100 /�measure�by�heat�sink,�near�transformer
OVER�TEMPERATURE
Protection�type�:�Shut�down�o/p�voltage, recovers�automatically�after�temperature�goes�down
-20�~�+65 (Refer�to�output�load�derating�curve)
WORKING�TEMP.
20�~�90%�RH�non-condensing
WORKING�HUMIDITY
-20~+85
10~95%�RH
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
ENVIRONMENT
0.04%�/ (0~50
)
10~200Hz,�2G�10min./1cycle,�60min.�each�along�X, Y,�Z�axes
SAFETY STANDARDS
WITHSTAND�VOLTAGE
UL60950, TUV�EN60950 Approved
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
SAFETY & ISOLATION�RESISTANCE
I/P-O/P,�I/P-FG,�OP/FG:100M�Ohms�/�500VDC
Compliance�to�EN55022�(CISPR22)�class A
Compliance�to EN61000-3-2,3
EMC
(Note.�5)
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
POWER�GOOD�SIGNAL
SPECIAL FUNCTION
COOLING
Compliance�to EN61000-4-2,3,4,5,6,8,11,�Light�industry�level,��criteria A
Open�collector�of�NPN�transistor
DC�Voltage Adj.,�Remote�sensing,�remote�control,�parallel�operation(refer�to�control�terminal�instruction�manual)
By�fan,�>20%�load�or�>50 fan�on
OTHERS
NOTE
MTBF
24.9K�hrs�min.����MIL-HDBK-217F(25
350*212*124mm�(L*W*H)
)
DIMENSION
9.0kg�;���1pcs�/�10kg�/�CARTON
PACKING
ꢇꢚꢁ�ꢥꢥꢁꢄꢦꢑꢦꢩꢒꢆꢒꢑꢞꢁꢭꢣꢷꢁꢞꢄꢒꢝꢂꢦꢥꢥꢳꢁꢩꢒꢃꢆꢂꢓꢃꢒꢧꢁꢦꢑꢒꢁꢩꢒꢦꢞꢅꢑꢒꢧꢁꢦꢆꢁꢋꢏꢉꢍ�ꢀꢁꢂꢃꢄꢅꢆꢎꢁꢑꢦꢆꢒꢧꢁꢥꢓꢦꢧꢁꢦꢃꢧꢁꢋꢵ ꢓꢬꢁꢦꢩꢲꢂꢒꢃꢆꢁꢆꢒꢩꢄꢒꢑꢦꢆꢅꢑꢒꢚ
ꢋꢚꢁꢸꢂꢄꢄꢥꢒꢁꢹꢁꢃꢓꢂꢞꢒꢁꢦꢑꢒꢁꢩꢒꢦꢞꢅꢑꢒꢧꢁꢦꢆꢁꢋꢉꢺꢻꢼꢁꢓꢬꢁꢲꢦꢃꢧꢐꢂꢧꢆꢡꢁꢲꢳꢁꢅꢞꢂꢃꢨꢁꢦꢁꢇꢋꢽꢁꢆꢐꢂꢞꢆꢒꢧꢁꢄꢦꢂꢑꢫꢐꢂꢑꢒꢁꢆꢒꢑꢩꢂꢃꢦꢆꢒꢧꢁꢐꢂꢆꢡꢁꢦꢁꢉꢚꢇꢅꢬꢁꢹꢁꢔꢾꢅꢬꢁꢄꢦꢑꢦꢥꢥꢒꢥꢁꢝꢦꢄꢦꢝꢂꢆꢓꢑꢚ
ꢏꢚꢁꢷꢓꢥꢒꢑꢦꢃꢝꢒꢁꢟꢁꢂꢃꢝꢥꢅꢧꢒꢞꢁꢞꢒꢆꢁꢅꢄꢁꢆꢓꢥꢒꢑꢦꢃꢝꢒꢎꢁꢥꢂꢃꢒꢁꢑꢒꢨꢅꢥꢦꢆꢂꢓꢃꢁꢦꢃꢧꢁꢥꢓꢦꢧꢁꢑꢒꢨꢅꢥꢦꢆꢂꢓꢃꢚ
ꢔꢚꢁꢀꢅꢑꢑꢒꢃꢆꢁꢥꢂꢩꢂꢆꢂꢃꢨꢁꢏꢁꢆꢂꢩꢒꢞꢕꢇꢚꢵꢞꢎꢏꢚꢉꢞꢎꢵꢚꢉꢞꢖꢷꢡꢒꢃꢁꢂꢃꢆꢒꢥꢥꢂꢨꢒꢃꢆꢁꢦꢅꢆꢓꢁꢑꢒꢝꢓꢤꢒꢑꢳꢁꢲꢒꢬꢓꢑꢒꢁꢞꢡꢅꢆꢁꢧꢓꢐꢃ
ꢵꢚꢁꢷꢡꢒꢁꢄꢓꢐꢒꢑꢁꢞꢅꢄꢄꢥꢳꢁꢂꢞꢁꢝꢓꢃꢞꢂꢧꢒꢑꢒꢧꢁꢦꢁꢝꢓꢩꢄꢓꢃꢒꢃꢆꢁꢐꢡꢂꢝꢡꢁꢐꢂꢥꢥꢁꢲꢒꢁꢂꢃꢞꢆꢦꢥꢥꢒꢧꢁꢂꢃꢆꢓꢁꢦꢁꢬꢂꢃꢦꢥꢁꢒꢿꢅꢂꢄꢩꢒꢃꢆꢚꢁꢷꢡꢒꢁꢬꢂꢃꢦꢥꢁꢒꢿꢅꢂꢄꢩꢒꢃꢆꢁꢩꢅꢞꢆꢁꢲꢒꢁꢑꢒꢫꢝꢓꢃꢬꢂꢑꢩꢒꢧꢁꢆꢡꢦꢆꢁꢂꢆꢁꢞꢆꢂꢥꢥꢁꢩꢒꢒꢆꢞ
ꣀꢺꢀꢁꢧꢂꢑꢒꢝꢆꢂꢤꢒꢞꢚ
300 Myles Standish Blvd., Taunton, MA 02780
WWW.ASTRODYNE.COM
ph: 1-800-823-8082
Fax: 508-823-8181