S3A THRU S3M
SURFACE MOUNT GENERAL RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 3.0 Ampere
FEATURES
SMC ( DO-214AB )
●
The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
For surface mounted applications
Low reverse leakage
Built-in strain relief,ideal for automated placement
High forward surge current capability
High temperature soldering guaranteed:
250 C/10 seconds at terminals
●
.128(3.25)
.108(2.75)
●
●
●
●
.245(6.22)
.220(5.59)
.280(7.11)
.260(6.60)
.012(.305)
.006(.152)
.103(2.62)
.079(2.00)
MECHANICAL DATA
Case: JEDEC SMC/DO-214AB molded plastic body
Terminals: Solder plated , solderable per MIL-STD-750,
Method 2026
.008(.203)
.002(.051)
.060(1.52)
.030(0.76)
.320(8.13)
.305(7.75)
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight:0.007 ounce, 0.24grams
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics @TA=25°C unless otherwise specified
Characteristic
Symbol
Unit
S3B
S3G
S3A
S3D
S3J
600
420
S3K
800
560
S3M
1000
700
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
VRRM
V
RWM
50
35
100
70
200
140
400
V
V
R
RMS Reverse Voltage
VR(RMS)
I O
280
3.0
V
A
Average Rectified Output Current @TL = 75°C
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave superimposed on
rated load (JEDEC Method)
FSM
I
100
A
Forward Voltage
@IF = 3.0A
VFM
IRM
Cj
1.10
V
Peak Reverse Current
At Rated DC Blocking Voltage
@TA = 25°C
@TA = 125°C
5.0
250
µA
Typical Junction Capacitance (Note 2)
Typical Thermal Resistance (Note 3)
Operating and Storage Temperature Range
60
13
pF
°C/W
°C
R
JL
Tj, TSTG
-55 to +150°C
Note: 1. Measured with IF = 0.5A, IR = 1.0A, Irr = 0.25A,
2. Measured at 1.0 MHz and applied reverse voltage of 4.0 V DC.
3. Mounted on P.C. Board with 8.0mm2 land area.