General Purpose Relays
Miniature Power PCB Relay RY II
I
I
I
I
I
I
I
I
I
1 pole 8 A, 1 CO or 1 NO or 1 NC contact
Low component height 12.3 mm
5 kV / 8 mm coil-contact
Reinforced insulation (protection class II)
Pinnings: 3.2 and 5 mm
Sockets with PCB-type or screw-type terminals
Especially suitable for resistive and inductive loads on NO and NC contacts
Plastic materials according to IEC60335-1 (domestic appliances)
RoHS compliant (Directive 2002 / 95 / EC) as per product date code 0403
Applications: heating control, interface technology, domestic appliances,
timers, temperature control
F0142-C
Approvals
V
REG.-Nr. 5358,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
1CO or 1NO or 1NC
single contact
micro disconnection
8 A
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Contact material
240/400 VAC
2000 VA
AgNi0,15, AgSnO2, AgCdO
30x106 cycles
6 / 1200 min-1
Mechanical endurance
Rated frequency of operation with / without load
Contact ratings
Type
Load
Cycles
RY610 B300, 120 VAC, 70°C, UL508
RY610 B300, 240 VAC, 70°C, UL508
RY610 1/4 hp, 120 VAC, 70°C, UL508
RY610 1/2 hp, 240 VAC, 70°C, UL508
RY610 8 A, 28 VDC,70°C, UL508
RY610 0.28 A, 250 VDC, 70°C, UL508
RY531 6 (4) A,250 VAC, 85°C, VDE 0631
>3x104
>3x104
1x105
Coil data
Rated coil voltage range DC coil
Coil power DC coil
Operative range
5...60 VDC
typ. 220 mW
2
Coil versions, DC-coil
Coil
Rated
Operate
voltage
VDC
3.5
Release
voltage
VDC
0.5
Coil
resistance
Ohm
112+10%
162+10%
320+10%
627+10%
2350+10%
9391+10%
14000+10%
Rated coil
code
voltage
power
mW
223
222
253
230
245
245
257
VDC
5
005
006
009
012
024
048
060
6
4.2
0.6
9
6.3
8.4
16.8
33.6
42.0
0.9
12
24
48
60
1.2
2.4
4.8
6.0
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2005/11
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to