15W Single Output Switching Power Supply
RS-15 series
■ Features :
#Universal AC input / Full range
#Protections: Short circuit / Overload / Over voltage / Over temperature
#Cooling by free air convection
#LED indicator for power on
#100% full load burn-in test
#All using 105℃ long life electrolytic capacitors
#Withstand 300VAC surge input for 5 second
#High operating temperature up to 70℃
#Withstand 5G vibration test
#High efficiency, long life and high reliability
#3 years warranty
..
SPECIFICATION
MODEL
RS-15-3.3
RS-15-5
RS-15-12
RS-15-15
RS-15-24
RS-15-48
DC VOLTAGE
3.3V
3A
5V
12V
15V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
3A
1.3A
1A
0.625A
0 ~ 0.625A
15W
0.313A
0 ~ 0.313A
15W
0 ~ 3A
9.9W
0 ~ 3A
15W
0 ~ 1.3A
15.6W
120mVp-p
10.8 ~ 13.2V
1.0%
0 ~ 1A
15W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 2.0%
80mVp-p
4.75 ~ 5.5V
2.0%
120mVp-p
13.5 ~ 16.5V
1.0%
200mVp-p
22 ~ 27.6V
1.0%
200mVp-p
43.2 ~ 52.8V
1.0%
OUTPUT
2.9 ~ 3.6V
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 30ms/230VAC
1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
70ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
15ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
72%
77%
81%
81%
82%
82%
INPUT
0.35A/115VAC
0.25A/230VAC
COLD START 65A / 230VAC
<2mA / 240VAC
Above 105% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V
28.4 ~ 32.4V
55.2 ~ 64.8V
OVER VOLTAGE
PROTECTION
Protection type : Shut off o/p voltage, clamping by zener diode
U1 Tj 140℃ typically (U1) detect on main control IC
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70℃ (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25℃ 70%RH
Compliance to EN55022 (CISPR22) Class B
SAFETY &
EMC
(Note 6)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
MTBF
1608.8Khrs min. MIL-HDBK-217F (25℃)
62.5*51*28mm (L*W*H)
OTHERS
NOTE
DIMENSION
0.13Kg; 108pcs/15Kg/0.71CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RS-15-SPEC 2007-10-25