5秒后页面跳转
R3-NML3-L3/CE PDF预览

R3-NML3-L3/CE

更新时间: 2022-05-14 22:19:13
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
5页 162K
描述
Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

R3-NML3-L3/CE 数据手册

 浏览型号R3-NML3-L3/CE的Datasheet PDF文件第1页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第2页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第3页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第5页 
MODEL: R3-NML3  
■ ANALOG DATA (16-bit data, models: R3-CT4A, CT4B, etc.)  
16-bit binary data.  
Integer obtained by multiplying unit value (A) by 100.  
In case of CLSE-R5, integer obtained by multiplying unit value (A) by 1000.  
15  
0
■ ACCUMULATED COUNT DATA (32-bit data, models: R3-PA2, PA4A, WT1, WT4, etc.)  
32-bit binary data is used for accumulated counts and encoder positions.  
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.  
15  
0
0
+0  
+1  
Lower 16 bits  
Higher 16 bits  
15  
■ BCD DATA (32-bit data, models: R3-BA32A, BC32A, etc.)  
32-bit binary data is used for BCD.  
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.  
15  
15  
0
+0  
+1  
Lower 16 bits  
Higher 16 bits  
0
■ 16-POINT DISCRETE DATA (models: R3-DA16, DC16, etc.)  
15  
0
Input 1 (Output 1)  
Input 2 (Output 2)  
Input 3 (Output 3)  
:
:
Input 16 (Output 16)  
0 : OFF  
1 : ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
27.5 [1.08]  
109 [4.29]  
POSITIONING  
GUIDE  
6-M3  
SCREW  
1
4
2
5
3
6
TERMINAL  
COVER  
R3-NML3 SPECIFICATIONS  
ES-8336 Rev.6 Page 4/5  
https://www.m-system.co.jp/  

与R3-NML3-L3/CE相关器件

型号 品牌 描述 获取价格 数据表
R3-NML3-L3/Q MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N/CE MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N/Q MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-R MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-R/CE MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格