5秒后页面跳转
R3-NML3-L3/CE PDF预览

R3-NML3-L3/CE

更新时间: 2022-05-14 22:19:13
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
5页 162K
描述
Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

R3-NML3-L3/CE 数据手册

 浏览型号R3-NML3-L3/CE的Datasheet PDF文件第1页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第2页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第4页浏览型号R3-NML3-L3/CE的Datasheet PDF文件第5页 
MODEL: R3-NML3  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
C
Station No.  
SA1  
SA2  
4
C
Rotary SW (x10)  
Station No.  
Rotary SW (x1)  
4
RUN LED  
ERR LED  
LNK1  
LNK2  
Functions  
LNK 1 LED  
LNK 2 LED  
SW3  
ON  
SW2  
SW1  
LNK1  
LNK2  
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Configuration Jack  
MECHATROLINK - III  
LINK 1 Connector  
1
MECHATROLINK - III  
LINK 2 Connector  
4
5
6
2
3
ON  
ON  
MECHATROLINK RELATED COMMANDS  
Commands available with this unit are the following.  
PROFILE  
COMMAND  
NOP  
CODE  
00H  
03H  
04H  
05H  
06H  
0EH  
0FH  
20H  
FUNCTION  
Common command  
No operation command  
Read ID command  
ID_RD  
CONFIG  
Setup device command  
ALM_RD  
ALM_CLR  
CONNECT  
DISCONNECT  
DATA_RWA  
Read alarm or warning command  
Clear alarm or warning command  
Establish connection command  
Release connection command  
Transmit I/O data  
Standard I/O pro!le  
I/O DATA DESCRIPTIONS  
The data allocations for typical I/O modules are shown below.  
Refer to the manual for each module for detailed data allocations.  
■ ANALOG DATA (16-bit data, models: R3-SV4, YV4, DS4, YS4, US4, etc.)  
16-bit binary data.  
Basically, 0 to 100% of the selected I/O range is converted into 0 to 10000 (binary).  
-15 to 0 % is a negative range represented in 2’s complement.  
In case of R3-US4, -10 to 0% is a negative range represented in 2's complement.  
15  
0
■ TEMPERATURE DATA (16-bit data, models: R3-RS4, TS4, US4, etc.)  
16-bit binary data.  
With °C temperature unit, raw data is multiplied by 10. For example, 25.5°C is converted into 255.  
With °F temperature unit, the integer section of raw data is directly converted into the data.  
For example, 135.4°F is converted into 135.  
Minus temperature is converted into negative values, represented in 2’s complements.  
15  
0
R3-NML3 SPECIFICATIONS  
ES-8336 Rev.6 Page 3/5  
https://www.m-system.co.jp/  

与R3-NML3-L3/CE相关器件

型号 品牌 描述 获取价格 数据表
R3-NML3-L3/Q MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N/CE MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-N/Q MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-R MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格

R3-NML3-R/CE MSYSTEM Remote I/O R3 Series MECHATROLINK INTERFACE MODULE

获取价格