60W Quad Output Switching Power Supply
Q-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 35KHz
2 years warranty
SPECIFICATION
MODEL
Q-60B
Q-60C
Q-60D
OUTPUT NUMBER
CH1
5V
CH2
12V
2A
CH3
-5V
CH4
CH1
5V
CH2
15V
1.5A
CH3
-5V
CH4
CH1
5V
CH2
12V
1A
CH3
24V
1A
CH4
-12V
0.5A
DC VOLTAGE
-12V
0.5A
0 ~ 1A
-15V
0.5A
0 ~ 1A
RATED CURRENT
CURRENT RANGE
RATED POWER
5.5A
0.5A
5.5A
0.5A
4A
0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A
60W
0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A
60W
0.5 ~ 8A 0.1 ~ 3A 0.1 ~ 1.5A 0 ~ 1A
62W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 150mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
OUTPUT
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
6.0%
1.0%
4.0%
5.0%
0.5%
1.0%
5.0%
0.5%
1.0%
2.0%
0.5%
0.5%
+8,-4%
2.0%
5.0%
0.5%
1.0%
5.0%
0.5%
1.0%
2.0%
0.5%
0.5%
6.0%
1.0%
4.0%
+8,-4%
2.0%
5.0%
0.5%
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.5%
4.0%
4.0%
800ms, 20ms/230VAC
1600ms, 20ms/115VAC at full load
70ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
70%
15ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
72%
75%
INPUT
2A/115VAC
0.8A/230VAC
COLD START 15A/115VAC
<1mA / 240VAC
30A/230VAC
LEAKAGE CURRENT
105 ~ 150%/115VAC rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75VDC
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
MTBF
284.8K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
DIMENSION
OTHERS
NOTE
0.56Kg; 24pcs/14.4Kg/0.75CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:Q-60-SPEC 2010-10-18